Closed surge tank initial water level

would be nice for the surge program, is to have the initial water level automatically calculated for closed surge tanks
Guest over 1 year ago in InfoWater Pro / Productivity 0 Gathering support

Extend flexibility in displaying information associated to HGL profiles

As an InfoWater user I'd like to be able to add more information to my HGL profile, including nodal pressure, pipe diameter, flow, velocity, etc. I'd like see max/min level achieved throughout the simulation and have the ability to quickly add pip...
Guest about 5 years ago in InfoWater Pro / Productivity 2 Gathering support

Export InfoSurge results for external application

InfoWater can use the option to "Export simulation results for external application" to export selected results to DBF files. It would be nice to have this work for InfoSurge.
Colin Ricks almost 4 years ago in InfoWater Pro 1 Gathering support

Adjust VSP "Control Value" during model run with Basic Controls

Seems like a fundamental control to be able to adjust a pump's target flow rate dynamically, for a high/low flow setpoint based on tank levels or other triggers. I can currently adjust the speed setting in basic rules, but trying to hit a target f...
Eric King over 1 year ago in InfoWater Pro / Operational Modeling 2 Gathering support

Limit InfoWater Pro Results Output for External Applications to Certain Runs

Currently, when using the "EXT_APP_FILTER" setting to output results in .dbf format for selected elements, .dbf files are created for every single scenario that is run, although the .dbf output files might not be needed for all scenarios. This unn...
Christene Razafimaharo over 1 year ago in InfoWater Pro / Productivity 0 Gathering support

Improve model maintenance

As a user I want to be able automate my model build maintenance activity so that my hydraulic model always reflects the asset repository
Guest over 5 years ago in InfoWater Pro 1 Gathering support

Isolation Scenario Using Dummy Valves Which Do Not Split Pipes

Can you put a valve on top of a pipe (not splitting the pipe) and then it closes the section? And then anything enclosed to these multiple valves will be isolated? This is going to be useful for modelling of isolation scenarios
Guest about 1 year ago in InfoWater Pro / Operational Modeling 3 Gathering support

Improvements to "Edit Attributes" table

The "Edit Attributes" window (accessed by using the "Edit Selection" or "Edit Domain" buttons) is a useful table to quickly view and edit all the physical information for each facility type together. However, it has some useability issues that som...
Colin Ricks about 1 year ago in InfoWater Pro / Productivity 0 Gathering support

Allow Customized Reports to Also Include Standard and Fireflow Results - Just Have One Result Table

Currently all model element information and results are separated between the DB Editor, Customizable Report, and Output Report/Graph. This is confusing and hard to export specific information together without having to combine it later in Excel o...
Joe Lawrence almost 4 years ago in InfoWater Pro 1 Gathering support

Hydrant and valve placement optimization

Hi there, We have been discussing the valve optimization in the whole County and if the InfoWater Pro can have the function to optimize the placements of hydrants and valves in the network to facilitate the design and high-level planning, that wou...
Guest over 1 year ago in InfoWater Pro / Productivity 1 Gathering support