Changes to a network do not propagate downstream

If you change a pipe diameter or gradient, it will not accommodate these changes in the downstream section of the network. For example upsizing and steepening a pipe in the middle of a run will mean the next pipeis undersized and goes uphill. It a...
Matthew Johnson over 1 year ago in InfoDrainage / Hydraulics 1 For Review

When importing BEFDSS CCTV surveys allow for update by ID.

When importing CCTV surveys following the BEFDSS (Belgian) standard, it's only possible to update existing surveys by matching on AAD + AAF + ABJ fields. It would make our lives a lot easier when it would be possible to update existing surveys by ...
Ward Delabastita 7 months ago in Other Product Ideas / Asset Management 0 For Review

Enable 3D video in defects tab of surveys

3D video can provide additional insight for sewer inspections (manhole & CCTV). As of now, the viewer in the defects tab doesn't have the standard panning functionality necessary for viewing 3D video.
Guest 11 months ago in Other Product Ideas / Asset Management 2 For Review

Option to remove the 1m access chamber from cellular storage design

For a start, its not clear that the software actually does this, except one line in the help. So would probably be a good idea to make that clear. But the main issue is that I either need to mess with the volume or the porosity to make the volume ...
Guest 3 months ago in InfoDrainage / Hydrology 0 For Review

Slope in %

It would be very handy if the slope input option of % be present regardless of Regional settings; being just 1:x is an important limitation; also, if the slope in % could be shown in the section views, would be nice.
Guest about 1 year ago in InfoDrainage / Hydraulics 0 For Review

Order Junction & Connection Results Printout by Flowpath (to match the Model Printout)

Issue: When using the 'print' feature, if a flow path is selected, the model summary for junctions will show ALL connected pipes, in 'flow' order, which is very useful for presenting/understanding data. However, in the results tab for connections,...
Alex Purcell almost 2 years ago in InfoDrainage / Reporting 0 For Review

Results tables to be ordered from most upstream junction/connection to outfall

As per the title, currently the results tables are presented in numerical order - which doesn't always make sense when interpreting the results. I.e should be presented in the same order they were in Microdrainage.
Guest over 1 year ago in InfoDrainage / Reporting 0 For Review

SCS generation - automatically pull data

InfoDrainage says it 'Generate(s) SCS data' but it really just links to the SCS website. Can Autodesk refine this to be more like the NOAA Atlas 14 which really does pull the data automatically into InfoDrainage.
Tim Medearis 11 months ago in InfoDrainage / Rainfall 0 For Review

Info Asset Online enable 3D video in defects tab of surveys

According to the latest standards for manhole inspection, our measurement data is provided in 3D. Unfortunately, there is no option to present it in this format in IAO.
Ewa Denys 4 months ago in Other Product Ideas / Asset Management 0 For Review

Adding 'Fall' of connections to tables and make editable

in the editing table we only have slope, and invert levels to edit connections. It would be greatly useful if the fall was added to a the pipe data table so this can be viewed and edited where. particularly for maintaining level soffits and check ...
Guest 7 months ago in InfoDrainage 0 For Review