Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

InfoWorks ICM

Showing 442

AutoCAD objects on Conversion

As a user, I would like InfoWorks to recoginze Civil3D objects as objects and not require me to resolve the model to dumb elements
Guest about 6 years ago in InfoWorks ICM / Hydraulics / Import data / Terrain 0 Gathering support

Play/Pause button

Current play and pause buttons (when viewing simulation results) are separate. I realise there are step buttons but if I want to start/stop quickly, whilst looking at the results instead of where the mouse is, then it's more convenient as a single...
Matthew Paul over 1 year ago in InfoWorks ICM / Productivity 0 Gathering support

Need additional Timestep function for "Between episodes" of "Simulation runoff only"

It needs creating a new Timestep function in ICM Run window that allows setting up timestep for "Simulation runoff only" for the "Between episodes" separately with "Timestep (s)" in Run window. This new function saves a lot of running time when th...
Guest about 3 years ago in InfoWorks ICM / Events / Simulations 0 Gathering support

ICM SWMM should show the Pipe Slope and Full Flow (PFC) on the Properties Dialog

While it might seem like a small detail, the ability to access the same properties on a Grid in ICM SWMM that were available in InfoSWMM can significantly enhance user experience. Many users request to see properties such as pipe slope and PFC val...
Robert Dickinson over 1 year ago in InfoWorks ICM / Grids 0 Gathering support

Infoworks ICM - Contours and Labels

Infoworks - ICM Contours with labels to be shown on ground model
Guest over 5 years ago in InfoWorks ICM / Terrain 1 Gathering support

ICM - HEC-22 Combination Inlet for continuous grade inlets

Currently ICM has 6 FWHA Gully Inlet types: ContCo Continuous Curb Opening ContG Continuous Grate SagC Sag Combination SagCO Sag Curb Opening SagG Sag Grate and UPC Grate A commonly used Inlet type (particularly in QLD Australia) that is missing ...
Guest about 3 years ago in InfoWorks ICM / Hydraulics 0 Gathering support

Interpolation of levels

It happens too often that while merging different models, you suddenly need a different timestep for your level-file. The only way to do this now, is remake your level completely. It would be better to (when changing the timestep of your level) IC...
Guest over 5 years ago in InfoWorks ICM / Events / Productivity 1 Gathering support

Drain nodes connected to 2d domain representing road gullies to 1D pipe network without digitised connection

Often datasets of road gullies are only in point format and lack details on the connections to the surface water sewer network. A function to allow 1D nodes representing road gullies (which are are connected to the 2D domain with a head discharge ...
Guest over 1 year ago in InfoWorks ICM / Inlets 0 Gathering support

Correct calculation of volume within storage node when using porosity

Currently when a porosity value is applied to a storage node, the porosity is only applied for storage array entries which are below ground level. Storage array entries above ground level are assumed to have a porosity of 100%. Between the highest...
Lizzie about 4 years ago in InfoWorks ICM / Hydraulics 1 Gathering support

Control units precision in long plots and grid plots

it would be nice to be able to control unit precision such as volume in m3 to a whole number when reported volume is in the 400000 m3. we do not need to see 4 digits past the decimal!!
John Krpan over 1 year ago in InfoWorks ICM / Long Section / Profile 0 Gathering support