Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

InfoWorks ICM

Showing 21

reduce validation time of models with infiltration zones

When using rainfall onto mesh in InfoWorks ICM, we often rely on infiltration zones to represent different land uses and their runoff characteristics (e.g., impermeable surfaces, grass, etc.). To ensure full coverage and avoid gaps or "donuts" in ...
Coen Maas 4 months ago in InfoWorks ICM / Validation 2 For Review

Pop out windows for tabs

This would be useful so then one would be able to view multiple long-sections and view the map at the same time on different screens, rather than being limited to one tab at a time.
Guest 4 months ago in InfoWorks ICM / Visualization 1 For Review

Add section results to profile view

I would like to view the water level (or velocity, froude number etc...) at each cross section when displaying a river reach long profile.
Raphael BAUBION 5 months ago in InfoWorks ICM / Long Section / Profile 1 For Review

Antecedent conditions as a direct run input for design events

I would like an object similar to the 'Catchment Initial Conditions' object for the TSB, that would allow a user to directly specify and overwrite the initial NAPI value, soil store level and groundwater level, per each individual subcatchment, in...
Guest 9 months ago in InfoWorks ICM / Rainfall 0 For Review

Allow export of user flags via ruby

As a WaSC we hold our models in a central model library and need to ensure our default flags are utilised, and the descriptors are not amended. we have automated the comparison as far as possible but the flags within any new Db have to be manually...
Richard Robinson 10 months ago in InfoWorks ICM / Export Data 0 For Review

Display PRN file results in user units

It would be great to see results of a PRN file using the user defined units rather than just native metric units.
Karen Chu 8 months ago in InfoWorks ICM / Results 1 For Review

Pump Station Operation Narrative

Would like the ability to add a pump station narrative. For example, a station may have several pumps and varying set points, however those set points do not relate to a specific pump. The station may operate where once the first set point is reac...
Dave White about 1 year ago in InfoWorks ICM / Pumps 0 For Review

Change formatting of '2D level boundary below ground level' in the timestep log

Other warnings such as manhole shaft/chamber area occur with only one line of text with the '(and possibly others)' text. Could something similar be introduced for the '2D level boundary below ground level' warning in the timestep log? This warnin...
Tom Newman 10 months ago in InfoWorks ICM / Reporting 0 For Review

Import Z value from CAD/SIG 3D line to the Bridge Opening table of a 2D Bridge structure

When creating a user defined opening, it is really painfull to use the table editor. Why do not create an import feature that import X,Y an Z value from a 3D CAD line (such as the soffit CAD line) into the opening table property ? It will simplify...
Raphael BAUBION 5 months ago in InfoWorks ICM / InfoWorks 0 For Review

Option to change selection method to avoid the Multiple Selection dialogue

Often when I'm working on the GeoPlan, I want to select, identify, or label multiple nodes or links. Every time I click on one that intersects with a sub catchment though, I have to deal with the multiple selection dialogue and choose which featur...
Guest 10 months ago in InfoWorks ICM / Productivity 1 For Review