Pipe level difference in properties window

Pipe level drop (distance between upstream invert level and downstream invert level) is not listed in pipe properties (as it previously was in MicroDrainage). It would be useful as a designer may want to target a specific level drop rather than an...
Ian George 11 days ago in InfoDrainage 0 For Review

Add max pipe flow to the pipe properties window

Max pipe flow (theoretical pipe full) is not listed in pipe properties, as it was previously in MicroDrainage. It was a useful feature.
Ian George 11 days ago in InfoDrainage / Productivity 0 For Review

Downstream pipes matching soffits/inverts

Currently when making changes in InfoDrainage the downstream pipes do not automatically adjust to the lowest incoming pipe. This means we have to manually adjust (and usually then lock) most pipes which is a downgrade from MicroDrainage.I understa...
Ian George 11 days ago in InfoDrainage 0 For Review

Addition of infiltration flows to foul drainage models in subcatchment items

When designing foul pipe networks, client guidance often directs users to incorporate an allowance for infiltration into pipes from the surrounding ground water. This is applied in addition to foul flows currently defined using the Main Drainage/ ...
Michael McWhinnie 3 months ago in InfoDrainage / Hydraulics 0 For Review

Adding Babbit Formula

Requesting addition of Babbit formula peak factor calculation to Infodrainage program, providing comprehensive analysis for efficient and accurate design and decision-making since Babbit formula peak factor calculation method used in many standard...
Mohamad Azzam over 1 year ago in InfoDrainage / Hydraulics 2 Under consideration

Better Interoperability options

The InfoDrainage import tool in Civil 3D forces all model elements (Pipe Networks and SWC Surfaces/Featurelines/Corridors) into a single active drawing. This conflicts with standard Civil 3D workflows where Utility and Grading designs are maintain...
Guest 13 days ago in InfoDrainage / Civil3D Integration 0 For Review

Apply inlet template to grate only without overwriting the invert depth for the structure

We should be able to apply an inlet grate template to a structure without overwriting the structure's depth or other geometry. The current workflow requires manually applying templates and entering properties for sometimes hundreds of manholes, wh...
Daniel'le DeVoss 5 months ago in InfoDrainage / Hydraulics 0 For Review

Canadian Rainfall Data - Built-in Design Storms

Environment Canada has regional rainfall data that should be available automatically in InfoDrainage similar to the NOAA Design Storms currently available in the Rainfall/Pollutants Tab of the software. This is a pain point for Canadian users, as ...
Guest almost 2 years ago in InfoDrainage / Rainfall 1 Under consideration

Process statistical reports from Ruby and ICM Exchange.

As part of DWMP running TSR "en masse" may be a requirement.We would like to code these in and export the statistical report results onc ethey are complete.This would save a great deal of time and would be processed in the background.There will be...
Jose Pereira about 1 year ago in InfoWorks ICM / API / Exchange 1 Under consideration

weighted roughness value according to the % of rougness zone within the 2D element

We have more and more detailed data and detailed models. This results into very detailed land use polygons then very detailed roughness zones. It means that a 2D element can contain several roughness zones. Intead of using the barycenter of the 2D...
Armonie COSSALTER about 1 month ago in InfoWorks ICM / 2D Flooding 1 For Review