Adjust VSP "Control Value" during model run with Basic Controls

Seems like a fundamental control to be able to adjust a pump's target flow rate dynamically, for a high/low flow setpoint based on tank levels or other triggers. I can currently adjust the speed setting in basic rules, but trying to hit a target f...
Eric King over 2 years ago in InfoWater Pro / Operational Modeling 2 Gathering support

Max or Min Flow values should not depend on the pipe direction. i.e. the value being positive or negative depend on the pipe direction

Currently, if the flow direction through the pipe is opposite to the direction of the pipe drawn it shows as a negative flow value. So if the flow goes both direction during the run, smaller positive value shows as the maximum flow and larger nega...
Guest almost 5 years ago in InfoWorks WS Pro / Other 0 Gathering support

Limit InfoWater Pro Results Output for External Applications to Certain Runs

Currently, when using the "EXT_APP_FILTER" setting to output results in .dbf format for selected elements, .dbf files are created for every single scenario that is run, although the .dbf output files might not be needed for all scenarios. This unn...
Christene Razafimaharo over 2 years ago in InfoWater Pro / Productivity 0 Gathering support

Open/Closed Valve Control - Live Data

When using an open/closed valve, setting a time profile to describe the opening and closing pressures, it would be useful to be able to load values form Live Data. It should be possible to connect the valve to 2 different live datas: one live data...
Paolo Boiardi over 1 year ago in InfoWorks WS Pro / Engine 0 For Review

Report volume stored in all tanks

I can calculate volume from level, but it's an extra step and requires that I copy the run results out to Excel. It's even more difficult if I have a non-circular tank. Please include tank volume in the tank results and in the "System Demand" report.
Colin Ricks about 5 years ago in InfoWater Pro / Productivity 1 Gathering support

In some types of elements the result of the simulation between consecutive time step are very different (oscillations).

Simulation results very differents between consecutive calculation times in series or cascade regulation elements; such as, pressure regulating valves (PRV), float valves (FLV), pumps, ...
Juan Carlos Ortega over 2 years ago in InfoWorks WS Pro / Engine 2 Already exists

Insufficient channel modeling

Impossibility of simulating the operation of a "real" channel with different sections created by different cameras: derivation, shipones, ...
Juan Carlos Ortega over 2 years ago in InfoWorks WS Pro / Engine 0 In progress

Zoom to domain when inactive facilities selected

When inactive facilities are included in the domain, clicking the "Zoom domain" button only zooms to the extent of the active facilities in the domain. If only inactive facilities are part of the domain (no active facilities at all), then this but...
Colin Ricks over 2 years ago in InfoWater Pro / Productivity 0 Gathering support

To be able to graph refill/depletion rate and/or survival time on reservoirs and towers

in WS Pro
Guest over 5 years ago in InfoWorks WS Pro 1 Gathering support

WS Pro to allow for maxconc at node/hydrant

No description provided
Guest over 5 years ago in InfoWorks WS Pro / Water Quality 1 Gathering support