Skip to Main Content
Autodesk
ADD A NEW IDEA

All ideas

Max or Min Flow values should not depend on the pipe direction. i.e. the value being positive or negative depend on the pipe direction

Currently, if the flow direction through the pipe is opposite to the direction of the pipe drawn it shows as a negative flow value. So if the flow goes both direction during the run, smaller positive value shows as the maximum flow and larger nega...
Guest almost 6 years ago in InfoWorks WS Pro / Other 0 Gathering support

Horizontal surge tank equivalent diameter

I also am still assuming that if I want to model a horizontal tank, you must put in an equivalent diameter not the actual diameter.
Guest almost 3 years ago in InfoWater Pro / Productivity 0 Gathering support

Enable true 'zooming out' on graphs

I am not sure if this is intended behavior, or if it is actually a bug/oversight, but I would like to request the 'zoom out' tool zooms out from the CURRENT POSITION, by one zoom increment (so just the reverse of how the zoom in works using the mo...
Jason Kulsdom over 4 years ago in InfoWorks ICM / Reporting 1 Gathering support

Network Isolation Trace

The Network Isolation Trace functionality identifies regions of a Distribution Network that are isolated from a source of water.
Tony Andrews over 1 year ago in Info360 Asset / Product workflows 0 Gathering support

Pipe isolation tracing

The Pipe Isolation Trace functionality can be used to identify the nearest valves to be closed in order to isolate a selected pipe(s). The trace works outwards from selected pipes until the tracing tool reaches a valve node or the extents of the n...
Tony Andrews over 1 year ago in Info360 Asset / Product workflows 0 Gathering support

Detention Time Modelling

We would like the model to calculate detention time of sewer in a simulation. The idea is similar to water age calculation in WS. The aim is to use this as a proxy for odour study, in essence we would like to be able to create thematic maps to sho...
Guest almost 6 years ago in InfoWorks ICM / Reporting / Results / Wastewater 0 Gathering support

Prevent re-use of previously used IDs

Using the automatic node generation, when a node with a certain ID is removed, that ID can be re-used for a new node. This can be confusing when referring to nodes in lists/maps/..., certainly when those are created from different database version...
Caroline Vandendriessche over 1 year ago in Info360 Asset / Data Management 2 For Review

Save button to grey out when clicked to confirm you have clicked the button

When you click the save button, it would be nice to have some sort of verification. Either the box will auto close or the save button will grey out.
Guest almost 3 years ago in InfoWorks ICM 0 Gathering support

Consistency with tab location in menus

Custom graph tabs are located at the top and vast majority of the grid windows are at the bottom. It would be great to have a consistency.
Guest almost 3 years ago in InfoWorks ICM 1 Gathering support

Wet Well Graph

As a modeler, I would like to see a plot showing everything for a pump station in one place. See the attached figure. Inflow/outflow and the flows from each pump. The 3D chart helps a lot showing which line is which.
Guest over 4 years ago in InfoWorks ICM / Results 0 Gathering support