Option for "downstream node" when allocating demand by pipe

The current "farthest node" option I believe just places the demand at the opposite end of the pipe compared to the meter point. Instead I'd like an option for all the meter demands to be placed at the pipe's end node. "Downstream" would probably ...
Eric King 11 months ago in InfoWater Pro / Other 0 For Review

Hydrant Design Flow vs Available Flow!

I don't like the new update, which makes the available flow subject to a velocity constraint. In the previous version, the pressure constraint was on the hydrant flowing, while the design flow would consider the network pressure and pipes. They sh...
Guest 11 months ago in InfoWater Pro / Engine 0 For Review

Persistent Graphs in InfoWater/InfoWater Pro

Stored graphs aren't that great. Why not just make graphs persistent?
Guest almost 5 years ago in InfoWater Pro / Productivity 2 Under consideration

Data Sets

It would be very helpful if, for any data set that is created by creating a clone of another data set, you could keep track of that. Perhaps a visually branched system of data sets to see if any of the sets were created based on another set. That ...
Guest almost 5 years ago in InfoWater Pro 1 Under consideration

Horizontal surge tank equivalent diameter

I also am still assuming that if I want to model a horizontal tank, you must put in an equivalent diameter not the actual diameter.
Guest about 2 years ago in InfoWater Pro / Productivity 0 Gathering support

Improvements to custom DB table fields

1. Ability to modify the length of custom fields in the DB tables after they have been created. This is particularly a problem when you create a text field, but realize later it is too short. Another option would be to make the default text length...
Colin Ricks almost 6 years ago in InfoWater Pro 2 Under consideration

Adjust VSP "Control Value" during model run with Basic Controls

Seems like a fundamental control to be able to adjust a pump's target flow rate dynamically, for a high/low flow setpoint based on tank levels or other triggers. I can currently adjust the speed setting in basic rules, but trying to hit a target f...
Eric King over 2 years ago in InfoWater Pro / Operational Modeling 2 Gathering support

Improve model maintenance

As a user I want to be able automate my model build maintenance activity so that my hydraulic model always reflects the asset repository
Guest about 6 years ago in InfoWater Pro 1 Gathering support

Limit InfoWater Pro Results Output for External Applications to Certain Runs

Currently, when using the "EXT_APP_FILTER" setting to output results in .dbf format for selected elements, .dbf files are created for every single scenario that is run, although the .dbf output files might not be needed for all scenarios. This unn...
Christene Razafimaharo over 2 years ago in InfoWater Pro / Productivity 0 Gathering support

Report volume stored in all tanks

I can calculate volume from level, but it's an extra step and requires that I copy the run results out to Excel. It's even more difficult if I have a non-circular tank. Please include tank volume in the tank results and in the "System Demand" report.
Colin Ricks about 5 years ago in InfoWater Pro / Productivity 1 Gathering support