Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

Ideas

Showing 272 of 1442

Inlet pump

We are mode and more incorporating surface water systems in our ICM models and part of those systems are inlet pumps that respond to the downstream levels instead of the upstream levels. Up until now, the only way to achieve this is by creating an...
Marcel Glasbergen almost 3 years ago in InfoWorks ICM / Pumps / RTC 0 Gathering support

Move the Refresh Output checkbox

Refresh Output should be checked 99.9% of the time, if you accidentally uncheck it then you might unknowingly look at old results Map Displays do not update. Can this checkbox be moved to somewhere not in the Model Explorer so it is less likely to...
Grant Clemens over 1 year ago in InfoWater Pro / Productivity 0 Gathering support

Consistent names and icons

Use the same name for things everywhere. For example, in the Model Explorer there is a "Modeling" section. In the DB editor, the field listed in the "Modeling" section are found in the "Hydraulic data" tables. Icons are also often different in dif...
Colin Ricks about 1 year ago in InfoWater Pro / Productivity 0 For Review

Batch run should work for run types other than standard

Batch run can only do standard runs. It is currently not possible to do fire flow, surge, pipe break, etc., as batch. Maybe add "Simulation type" to the General tab of the scenario explorer?
Colin Ricks about 1 year ago in InfoWater Pro / Productivity 0 Gathering support

RTC updated to support scripting

It would be good to have RTCs available through direct scripting rather than through the RTC editor alone.
Ann Pugh over 6 years ago in InfoWorks ICM / API / Exchange / RTC 1 Gathering support

Option for "downstream node" when allocating demand by pipe

The current "farthest node" option I believe just places the demand at the opposite end of the pipe compared to the meter point. Instead I'd like an option for all the meter demands to be placed at the pipe's end node. "Downstream" would probably ...
Eric King about 1 year ago in InfoWater Pro / Other 0 For Review

Push Changes From Parent to Child(ren) Scenarios

Allow changes made in a parent scenario to push through and update all child scenarios unless that link is broken in the child scenario(s). This goes along with the improvement suggestion titled "Data Sets" by Kathryn Carreira. The Scenario and ...
Joe Lawrence almost 5 years ago in InfoWater Pro 4 Gathering support

Contours and Spot Elevation data for Elevation Extractor in InfoWater Pro

While rasters remain the best way to assign elevations throughout the model, InfoWater also supported other formats using interpolation such as contours and point elevation. Please add these file types in InfoWater Pro.
Guest over 4 years ago in InfoWater Pro / Data Exchange 0 Gathering support

Support for multiple screens

I would like to be able to work across multiple screens - plan view on one screen and long section/grid/graph on another.
Guest over 6 years ago in InfoWorks WS Pro 1 Will not implement

Pressure above GL

It would be beneficial to include a results field for residual pressure relative to ground level, as service level requirements are typically referenced to ground level rather than pipe invert levels. This software offers enhanced flexibility by a...
Parameswara Rao Narra 8 months ago in InfoWorks WS Pro / Modeler 0 Gathering support