Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

Ideas

Showing 163 of 1370

Multiple fixed tailwater elevations

Currently, the software allows users to set only one fixed tailwater elevation per outlet. However, users need the ability to set different fixed tailwater elevations for different storm events (e.g., 10-year, 25-year, 100-year storms).
Guest 10 months ago in InfoDrainage / Hydraulics 0 For Review

Automate the "geodatabase rebuild" troubleshooting process

When models start to behave erratically or sluggish, a common recommendation is to "rebuild the model geodatabase" as shown here: https://www.autodesk.com/support/technical/article/caas/sfdcarticles/sfdcarticles/Troubelshoot-Map-Issues.html It wou...
Grant Clemens over 1 year ago in InfoWater Pro / Automation 0 Gathering support

Junction Loss

There need to be more options for calculating junction loss. Having values for entry and exit loss isn't enough. Recommend HEC-22 and AASHTO at a minimum.
Guest over 1 year ago in InfoDrainage / Hydraulics 2 Gathering support

Could we add a preference to disable the popup to accept the most recent run data?

The popup is confusing, and we don't see a point in not accepting the latest run results.
Deb Smith 10 months ago in InfoWater Pro / Productivity 2 Gathering support

Need more inlet options

SSA has numerous inlet manufacturers and jurisdictions, including Caltrans, FDOT, Neenah, etc. These would be beneficial to have in InfoDrainage, including East Jordan inlets. Additionally, have depth vs flow curve option would be helpful as well.
Guest over 1 year ago in InfoDrainage / Hydraulics 0 For Review

Add a storage structure feature for channel drains

Add a storage structure feature for channel drains (e.g. channel, slot drain, kerb drain) so that these features can be presented as storage and not only conveyance (by modelling a custom section) and so that catchments can be connected as a sheet...
Oliver Dodd about 1 year ago in InfoDrainage / Hydraulics 0 For Review

Vary infiltration with depth

Cannot currently use the software for deisgn of borehole soakaways. By their very nature they wil have varying infiltration rates. Usually the infiltration is at greatest depth and no way of modelling with correct head in borehole.
Guest 11 months ago in InfoDrainage / Hydraulics 1 For Review

Option to relate split pipe ID to original ID

When splitting pipes, the new ID for the resulting pipe is based on the ID and Description tab in the model's Preferences. Instead of going with those settings, it would be nice to have an option to enable that would instead take the original ID a...
Kim Solberg over 1 year ago in InfoWater Pro / Other / Productivity 0 Gathering support

Export manager scope should include Selection Sets

Export manager "Element Scope" currently only allows All, Domain, and User selection for the scope of the elements to export. A combo box with the list of selection sets would be useful and likely easy to implement.
Colin Ricks almost 2 years ago in InfoWater Pro / Productivity 0 Gathering support

Show preliminary sizing estimated flow depth in profile view.

The proportional depth is given in the Network Design Report but not shown in the long sections. This is a very useful feature to allow quick checking of throttling or spare capacity in the network.
Matthew Johnson about 1 year ago in InfoDrainage / Hydraulics 0 For Review