add HL/1000 to graphs

When you create a graph object to graph data from objects for multiple simulations against each other, there is no option to add HL/1000 data. Everything else is there but HL/1000 is missing. Please add this to the list.
Ben Davies over 2 years ago in InfoWorks WS Pro / Other 0 Gathering support

Exclude specific elements from Numbering Scheme (flow paths, manholes, simple junctions, etc).

Be able to have only manholes in the manhole schedule, without any missing manhole numbers. Junctions can be named separately and not included. Enable large sites with multiple areas to have their different areas named a different way easier.
Guest over 1 year ago in InfoDrainage / Auditing / Reviewing 2 Gathering support

Update downstream pipes

It would be useful to have an option to upsize downstream pipes automatically (just like microdrainage). For example, if i increase pipe size the corresponding downstream pipes should upsize accordingly so not to cause a restriction. At the minute...
Guest over 2 years ago in InfoDrainage / Productivity 2 Already exists

Improve Theme Symbol Support

While setting up a custom theme to align WS Pro more closely to our GIS, I've found the support for symbols quite limited, and think these would be worthwhile improvements: Support the use of custom SVG icons, and/or Support the use of non-system...
Dave Watts 10 months ago in InfoWorks WS Pro / Other 0 Gathering support

Allow underdrains to be displayed in the connection tables and add pipe number to them

It is very difficult to create a quick and logical pipe schedule when pipes such as underdrains are hidden in the SuDS nodes and their upstream invert level needs to be calculated manually. Please add the underdrains to the connection tables with ...
Iwona Savas 11 months ago in InfoDrainage 0 For Review

Infiltration Trench using BRE DIGEST 365 method

The software needs to support for designing Infiltration trench method by using “BRE DIGEST 365”. I have checked the comparison between Infodrainage analysis Vs BRE digest 365 (manual calculation) and the results are not matching. Most of the proj...
Guest almost 2 years ago in InfoDrainage / Hydraulics 8 Gathering support

Swale with pipe under connected by manholes

Could not model real-life scenario where the pipe was under as conveyance for lesser events and raised via vented manholes into the swale above. Need integrated solution and was unable to model both and connect via manholes.
Guest almost 2 years ago in InfoDrainage / Hydraulics 1 Already exists

Basemap support

The current x64 version of WS Pro doesn't seem to be able to use the ArcEngine / ArcGIS Desktop functionality, in contrast to previous x32 bit versions? Since only x64 bit version is now supported, this feature cannot be used. It is one of the mos...
Guest almost 2 years ago in InfoWorks WS Pro / Other 2 In progress

Correct resizing of pop-up windows activated through C3D toolbar

Due to issues with my eyesight I use the accessibility settings on my computer to increase the standard text sizes for applications. When using the InfoDrainage toolbar in Civil 3D pop-up menus don't resize to match the updated display settings. I...
Michael McWhinnie about 1 year ago in InfoDrainage / Other 0 For Review

Microdrainge to Revit

Make Pipes and Inlet available in Revit
Guest about 3 years ago in InfoDrainage 0 Gathering support