Skip to Main Content
Autodesk
ADD A NEW IDEA

InfoWater Pro

Showing 4

"Initially Closed" and "Check Valve Direction" symbology should adhere to the "show inactive elements" toggle

This is simple enough to do by adding a definition query on the MOTYPE field in conjunction with the existing DSPCODE filter, but currently I would have to manually change this for 4 layers every time I toggle display of inactive elements.
Eric King 4 months ago in InfoWater Pro / Other 1 In progress

Ability to utilize an alternative asset ID for the Info360 Asset/Info360 Insight integration

Unfortunately, sometimes the InfoWater Pro model has different asset IDs compared to the source asset GIS. This makes the InfoWater Pro integration with Info360 Asset and Info360 Insight unusable when the source GIS is used in these products. The ...
Martha Nunez about 1 year ago in InfoWater Pro / Data Exchange 0 In progress

Splitting pipe - surge wave speed not inherited

When splitting a pipe by inserting a node, the new pipe inherits the attributes of the original pipe (diameter, roughness, zone, material, etc). However, if the pipe has a wave speed assigned for surge modeling, the new pipe does not inherit the w...
Colin Ricks over 1 year ago in InfoWater Pro / Productivity 1 In progress

Include an "excluded search nodes" warning in fireflow output table

When the design pressure exceeds the static pressure at a particular node, that node will be excluded from a design fireflow model run. The output table should include a banner at the top listing the excluded nodes, as these can make a big differe...
Guest about 4 years ago in InfoWater Pro / Engine 0 In progress