Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

InfoWater Pro

Showing 16

Provide a "Remove elements from domain" option within DB Editor, Edit Domain Attributes, and tabular results report

I would like to be able to remove items from the domain as I review them within DB Editor, Edit Domain Attributes, and tabular results report tables, similar to the "Append to Domain" available when "right clicking" on an item in DB Editor.
Guest about 1 month ago in InfoWater Pro / Productivity 0 For Review

Easily query model results

Add the ability to easily query model results, such as: Junctions with pressure less than ## Pipelines with velocities higher than ## Valves with flow greater than ## etc. These could be added to a domain or viewed in the report manager. This is a...
Guest 8 months ago in InfoWater Pro / Productivity 2 For Review

Option to "remember my choice" on the Query Set Cache pop-up

The pop-up asking whether to use the cache or re-run Query Sets every time you switch scenarios can get annoying. It would be nice to have a checkbox that says "always re-run queries" or something to that effect so that this pop-up can be suppressed.
Grant Clemens about 2 months ago in InfoWater Pro / Productivity 0 For Review

InfoSurge constant reporting interval

Often, different InfoSurge runs report results at different intervals, even though the simulation duration is the same. This makes it difficult to do comparisons of results. Please allow the user to set a report timestep like you can with a standa...
Colin Ricks 3 months ago in InfoWater Pro / Productivity 0 For Review

InfoSurge velocity results

Please add pipeline velocities to the results for surge simulations. This really helps when designing surge tanks and connecting pipelines.
Guest 8 months ago in InfoWater Pro / Engine 1 For Review

Hydrant Available vs. Hydrant Design

Has anyone had issues with the hydrant available flow being less than the hydrant design flow? It has always been my impression that the hydrant available flow has less constraints and therefore would have a higher fire flow than that of the hydra...
Guest about 1 year ago in InfoWater Pro / Automation 1 For Review

Delete Vertex in Pipe

I would like to be able to remove vertices from a pipe. Currently, you can only move the vertices or redraw the pipe. This process takes a while on big models and makes the distribution network more complicated.
Guest 6 months ago in InfoWater Pro / Other 0 For Review

Pressure Relief Valve

Which valve, if any, would represent a pressure relief valve? Where the pressure on the upstream is not allowed to exceed a certain psi. If it exceeds the specified pressure on the upstream side the valve will open.
Guest 11 months ago in InfoWater Pro / Operational Modeling 2 For Review

By default display ID in alphabetical order in Control Center Overview in InfoWater Pro

By default display ID in alphabetical order in Control Center Overview in InfoWater Pro
Mickey Liu 10 months ago in InfoWater Pro 0 For Review

Consistent names and icons

Use the same name for things everywhere. For example, in the Model Explorer there is a "Modeling" section. In the DB editor, the field listed in the "Modeling" section are found in the "Hydraulic data" tables. Icons are also often different in dif...
Colin Ricks 10 months ago in InfoWater Pro / Productivity 0 For Review