Skip to Main Content
Autodesk
ADD A NEW IDEA

InfoWater Pro

Showing 15

Allow Constant Water Level in Tanks

We frequently need to run multiple time steps on steady-state simulations. Currently, to maintain a constant water surface elevation, we use a Reservoir element instead of a Tank. As a result, our models now include both a Tank (for non-steady-sta...
Joshua Alexander 10 days ago in InfoWater Pro / Productivity 0 For Review

Easily query model results

Add the ability to easily query model results, such as: Junctions with pressure less than ## Pipelines with velocities higher than ## Valves with flow greater than ## etc. These could be added to a domain or viewed in the report manager. This is a...
Guest 4 months ago in InfoWater Pro / Productivity 2 For Review

Delete Vertex in Pipe

I would like to be able to remove vertices from a pipe. Currently, you can only move the vertices or redraw the pipe. This process takes a while on big models and makes the distribution network more complicated.
Guest about 2 months ago in InfoWater Pro / Other 0 For Review

InfoSurge velocity results

Please add pipeline velocities to the results for surge simulations. This really helps when designing surge tanks and connecting pipelines.
Guest 3 months ago in InfoWater Pro / Engine 1 For Review

Hydrant Available vs. Hydrant Design

Has anyone had issues with the hydrant available flow being less than the hydrant design flow? It has always been my impression that the hydrant available flow has less constraints and therefore would have a higher fire flow than that of the hydra...
Guest 8 months ago in InfoWater Pro / Automation 1 For Review

Pressure Relief Valve

Which valve, if any, would represent a pressure relief valve? Where the pressure on the upstream is not allowed to exceed a certain psi. If it exceeds the specified pressure on the upstream side the valve will open.
Guest 7 months ago in InfoWater Pro / Operational Modeling 2 For Review

By default display ID in alphabetical order in Control Center Overview in InfoWater Pro

By default display ID in alphabetical order in Control Center Overview in InfoWater Pro
Mickey Liu 5 months ago in InfoWater Pro 0 For Review

Consistent names and icons

Use the same name for things everywhere. For example, in the Model Explorer there is a "Modeling" section. In the DB editor, the field listed in the "Modeling" section are found in the "Hydraulic data" tables. Icons are also often different in dif...
Colin Ricks 6 months ago in InfoWater Pro / Productivity 0 For Review

Batch run should work for run types other than standard

Batch run can only do standard runs. It is currently not possible to do fire flow, surge, pipe break, etc., as batch. Maybe add "Simulation type" to the General tab of the scenario explorer?
Colin Ricks 6 months ago in InfoWater Pro / Productivity 0 For Review

Add "Cloud" Run Mode for InfoWater Pro Surge simulations

IWP Surge has the unique ability to run surge simulations without the need to skeletonize the model. However, the Standard mode is currently the only option for running Surge simulations (Background and Cloud are not available). On larger models a...
Michael Kane 8 months ago in InfoWater Pro / Cloud Simulations 0 For Review