Addition of infiltration flows to foul drainage models in subcatchment items

When designing foul pipe networks, client guidance often directs users to incorporate an allowance for infiltration into pipes from the surrounding ground water. This is applied in addition to foul flows currently defined using the Main Drainage/ ...
Michael McWhinnie 3 months ago in InfoDrainage / Hydraulics 0 For Review

Adding Babbit Formula

Requesting addition of Babbit formula peak factor calculation to Infodrainage program, providing comprehensive analysis for efficient and accurate design and decision-making since Babbit formula peak factor calculation method used in many standard...
Mohamad Azzam over 1 year ago in InfoDrainage / Hydraulics 2 Under consideration

Apply inlet template to grate only without overwriting the invert depth for the structure

We should be able to apply an inlet grate template to a structure without overwriting the structure's depth or other geometry. The current workflow requires manually applying templates and entering properties for sometimes hundreds of manholes, wh...
Daniel'le DeVoss 4 months ago in InfoDrainage / Hydraulics 0 For Review

Infiltration trench with varying depth.

It should be possible to design an infiltration trench where the long slope at the base of the trench is different to the slope at exceedance level i.e. the depth of the trench varies. Extremely useful for designing a trench that does not match fa...
Guest over 1 year ago in InfoDrainage / Hydraulics 0 For Review

Support for ArcEngine Functions for background layers (no x32 bit support)

The current x64 version of ICM cannot use the ArcEngine / ArcGIS Desktop funcionality, in contrast to previous x32 bit versions of ICM. Since only x64 bit version is now supported, this feature cannot be used. It is one of the most important featu...
Elliot Egan about 2 years ago in InfoWorks ICM / GIS Layers 1 In progress

Freeboard in Results

When freeboard is exceeded from something like a basin, it is not immediately clear in the stormwater control results. It says flood risk and a water level that eats into the freeboard, but it does not flag up that this is an issue and is easily m...
Guest 7 months ago in InfoDrainage / Hydraulics 0 For Review

Horizontal orifices as an outlet type

HydroCAD offers a horizontal orifice control outlet type that is very commonly used for detention pond outlet types in the US. Please include this as an outlet type so we can transition from HydroCAD to InfoDrainage.
Midori Patterson over 1 year ago in InfoDrainage / Hydraulics 1 Gathering support

possibility to connect labels to links at the beginning or end instead of only in the middle of the link

This way you can show that link invert levels on a manhole differ in value or deviate from the chamberfloor
Loes van der Linden 10 months ago in InfoWorks ICM / Labels 3 Already exists

Would it be possible to include longitudinal gradient (slope) to attenuation tanks please? At the moment it appears that software assumes that these structures are constructed flat whereas in real life these could be constructed with a gradient (slope) from the upstream end towards the outlet.

At the moment it appears that software assumes that these structures are constructed flat whereas in real life these could be constructed with a gradient (slope) from the upstream end towards the outlet (and this could then change the head of wate...
arek kadlec over 1 year ago in InfoDrainage / Hydraulics 1 Gathering support

Themes to include robust SQLs

Can we enhance conduit theming using robust SQL queries? We're aiming to apply themes based on the mean of minimum upstream and downstream velocities in each conduit over the TSR simulation. Considering the multiple scenarios involved in system de...
Parameswara Rao Narra 5 months ago in InfoWorks ICM / Theme 4 Already exists