Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

InfoDrainage

Showing 94

Retaining CAD files / Orphaning

When CAD files are imported to InfoDrainage they retain the link to the CAD file, like a CAD Xref which is good. However if that file is moved, or InfoDrainage cannot access it, an error box is prompted and the entire CAD file is just deleted from...
Ian George 1 day ago in InfoDrainage / Productivity 0 For Review

Permeable paving needs to have a option for a different gradient at the surface to the gradient at the base.

This would allow a better representation of steep sites where we would otherwise lose a lot of storage, instead we can make the base flat to allow for more storage volume.
Guest 25 days ago in InfoDrainage / Hydraulics 0 For Review

Foul Water Analysis

The ability to analyse foul water networks within Infodrainage is not fully supported. As we can build foul networks within Infodrainage, it would be helpful to output a set of calculations to demonstrate the suitability of the proposed network. C...
Morgan Harris 8 days ago in InfoDrainage / Hydraulics 0 For Review

Continuous Matched Soffits or Inverts Snapping

It would be useful if all pipes in a junction automatically snapped to match either soffits or inverts. There is a variable in the Network Design Criteria for 'Level Soffits' or 'Level Inverts' so potentially this option could be used for the live...
Ian George 18 days ago in InfoDrainage / Productivity 0 For Review

Option to remove the 1m access chamber from cellular storage design

For a start, its not clear that the software actually does this, except one line in the help. So would probably be a good idea to make that clear. But the main issue is that I either need to mess with the volume or the porosity to make the volume ...
Guest 23 days ago in InfoDrainage / Hydrology 0 For Review

Addition of infiltration flows to foul drainage models in subcatchment items

When designing foul pipe networks, client guidance often directs users to incorporate an allowance for infiltration into pipes from the surrounding ground water. This is applied in addition to foul flows currently defined using the Main Drainage/ ...
Michael McWhinnie 5 months ago in InfoDrainage / Hydraulics 0 For Review

Apply inlet template to grate only without overwriting the invert depth for the structure

We should be able to apply an inlet grate template to a structure without overwriting the structure's depth or other geometry. The current workflow requires manually applying templates and entering properties for sometimes hundreds of manholes, wh...
Daniel'le DeVoss 6 months ago in InfoDrainage / Hydraulics 0 For Review

Import Civil 3D Parts Lists to InfoDrainage

Currently, we can create parts lists in InfoDrainage and save them for reuse. However, it would be ideal if parts lists from Civil 3D could be imported directly into InfoDrainage.
Daniel'le DeVoss 6 months ago in InfoDrainage / Civil3D Integration 0 For Review

Add check dams as a feature for swales

Add a check dam setting with height, notch weir and interval settings to simplify modelling swales on sloping sites. This avoids having to model several sections of swale in order to use the available storage.
Oliver Dodd over 1 year ago in InfoDrainage / Hydraulics 0 For Review

Add max pipe flow to the pipe properties window

Max pipe flow (theoretical pipe full) is not listed in pipe properties, as it was previously in MicroDrainage. It was a useful feature.
Ian George about 2 months ago in InfoDrainage / Productivity 0 For Review