Provide option to allow for several multipliers and use with selection sets

In addition to a global multiplier, sometimes you want to peak certain areas and selection sets with specific peaking factors. WaterCAD allows for this under their calculation options.
Michele Marston over 1 year ago in InfoWater Pro / Operational Modeling 0 Gathering support

Evaluate Fireflow Minimum Pressure by Zone

In the drop down menu for the Critical Node Search Range, please add the option to evaluate minimum pressure based on the same zone. Or add an option to consider multiple search areas where the user can select either the entire system and/or by zo...
Joe Lawrence almost 5 years ago in InfoWater Pro 0 Gathering support

Export InfoSurge results for external application

InfoWater can use the option to "Export simulation results for external application" to export selected results to DBF files. It would be nice to have this work for InfoSurge.
Colin Ricks about 5 years ago in InfoWater Pro 1 Gathering support

I&I BizBlock for Wastewater Collection and Transmission

To be able to use SCADA/RTU volume readings from either gravity area/velocity meters or Lift Stations (with diameter and float level readings) to calculate volume. Then there a few statistical steps to sperate Inflow from Infiltration. Additionall...
Guest almost 5 years ago in Info360 Insight 0 Gathering support

GIS Gateway default Value

While updating the model from GIS and importing new objects, I want a user-defined Default value column for each field. If the source GIS is missing values, or there is no appropriate field to populate, fill in the model attribute using the defaul...
Nathan Gerdts almost 2 years ago in InfoWater Pro / Data Exchange 1 Gathering support

Report manager should populate without running model

Currently, the report manager is only populated once results are shown. This makes it so that the only place I can view the model data before running, is the data base manager. You should be able to have the report manager populated without runnin...
Endrit Shabani about 2 years ago in InfoWater Pro / Other 0 Gathering support

Horizontal surge tank equivalent diameter

I also am still assuming that if I want to model a horizontal tank, you must put in an equivalent diameter not the actual diameter.
Guest over 2 years ago in InfoWater Pro / Productivity 0 Gathering support

Sewer Lift Station Inflow Estimates

Sewer lift stations often have level and pump status data but not flow data which where the value is. We can estimate flow from other available sensors, and we need to do this efficiently for Miami.Due to the complexity and broad market applicatio...
Nathan Gerdts about 5 years ago in Info360 Insight 0 Gathering support

inlet riser option for tank

Have an option to specify an Inlet Riser Pipe for the tank element. This would hold the fill head at a constant, set at the riser pipe elevation, but allow the tank discharge head vary with the tank level.
Guest about 5 years ago in InfoWater Pro / Engine 1 Gathering support

Improve model maintenance

As a user I want to be able automate my model build maintenance activity so that my hydraulic model always reflects the asset repository
Guest over 6 years ago in InfoWater Pro 1 Gathering support