Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

Ideas

Showing 368 of 1442

Horizontal surge tank equivalent diameter

I also am still assuming that if I want to model a horizontal tank, you must put in an equivalent diameter not the actual diameter.
Guest over 2 years ago in InfoWater Pro / Productivity 0 Gathering support

Hydrant Design Flow vs Available Flow

I don't like the new update, which makes the available flow subject to a velocity constraint. In the previous version, the pressure constraint was on the hydrant flowing, while the design flow would consider the network pressure and pipes. They sh...
Guest about 1 year ago in InfoWater Pro / Engine 1 Already exists

Output to 2D CAD to have option of what units to export in.

When using the output to CAD function often when opening the file it says its in inches or ft. It would be good to have the option to change this to m or mm.
Guest over 2 years ago in InfoDrainage / Data Exchange 1 Gathering support

Improvements to custom DB table fields

1. Ability to modify the length of custom fields in the DB tables after they have been created. This is particularly a problem when you create a text field, but realize later it is too short. Another option would be to make the default text length...
Colin Ricks over 6 years ago in InfoWater Pro 2 Under consideration

inlet riser option for tank

Have an option to specify an Inlet Riser Pipe for the tank element. This would hold the fill head at a constant, set at the riser pipe elevation, but allow the tank discharge head vary with the tank level.
Guest about 5 years ago in InfoWater Pro / Engine 1 Gathering support

Improve model maintenance

As a user I want to be able automate my model build maintenance activity so that my hydraulic model always reflects the asset repository
Guest over 6 years ago in InfoWater Pro 1 Gathering support

Correct resizing of pop-up windows activated through C3D toolbar

Due to issues with my eyesight I use the accessibility settings on my computer to increase the standard text sizes for applications. When using the InfoDrainage toolbar in Civil 3D pop-up menus don't resize to match the updated display settings. I...
Michael McWhinnie over 1 year ago in InfoDrainage / Other 0 For Review

Report volume stored in all tanks

I can calculate volume from level, but it's an extra step and requires that I copy the run results out to Excel. It's even more difficult if I have a non-circular tank. Please include tank volume in the tank results and in the "System Demand" report.
Colin Ricks over 5 years ago in InfoWater Pro / Productivity 1 Gathering support

Adjust VSP "Control Value" during model run with Basic Controls

Seems like a fundamental control to be able to adjust a pump's target flow rate dynamically, for a high/low flow setpoint based on tank levels or other triggers. I can currently adjust the speed setting in basic rules, but trying to hit a target f...
Eric King almost 3 years ago in InfoWater Pro / Operational Modeling 2 Gathering support

Allow background mapping to be seen in plot plans

It would be good to allow shapefiles and other background mapping to be visible when creating a plot plan. Otherwise the location of pipework etc has no context.
Guest almost 3 years ago in InfoDrainage / Other 1 Gathering support