Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

Ideas

Showing 229 of 1370

Creation of the Pump element independent of its grouping in the Pumping Station as included in usual infrastructure catalogs (GIS)

Useful for maintaining the unique relationship between the elements of a supply network and the Infoworks model objects.
Juan Carlos Ortega over 2 years ago in InfoWorks WS Pro / Operations 2 Will not implement

The "join model" tool does not work correctly with Scenarios

The Infoworks Join Model Tool does not work correctly with Topologies and Controls containing different scenarios In the resulting united model, it maintains the four scenarios, but in all four scenarios the Topology and Control are the same, it r...
Juan Carlos Ortega over 2 years ago in InfoWorks WS Pro / Data Exchange 0 Gathering support

Respect the text separators of the operating system used by the equipment.

Respect the text separators of the operating system used by the equipment.
Juan Carlos Ortega over 2 years ago in InfoWorks WS Pro / Data Exchange 3 Gathering support

I would like more informative error messages when trying to Change an ID

I tried to change the ID for a pump, but I overlooked the “Target Element Type” dropdown, which was automatically set to junction. It took me a while to realize my mistake. It might be helpful to other users if the error messages/warnings (see be...
Guest over 5 years ago in InfoWater Pro / Productivity 0 Gathering support

InfoWater for QGIS

ArcMap and ArcGIS Pro are expensive and slow. QGIS is free and fast.
Colin Ricks over 5 years ago in InfoWater Pro 0 Will not implement

As a user of InfoWorks WS PRO, I would like to better simulate FMV valves

In InfoWorks WS PRO is possible to simulate FMV valves, but I would like to introduce a "deviation" option to better simulate it. I give an example: imagine a valve whose pressure setting is 2 Bar if flow is from 0 to 10 L/s, and 2.5 Bar if flow ...
Paolo Boiardi over 5 years ago in InfoWorks WS Pro / Engine 0 Gathering support

Add multiple rows to the InfoWater "Rule Header" DB table

In the "Pipe Control" or "Node Control" DB tables, I can insert or append multiple rows at once. In the "Rule Header" DB table, I can only insert or append one row at a time, and each row must have an ID. Please make the behavior of this table co...
Colin Ricks almost 3 years ago in InfoWater Pro 0 Under consideration

Add username to temp folder names to allow multiple users to model on the same cloud computer at the same time

Could InfoWater/InfoSWMM change how they name temp folders? Right now, if two users initialize a model on the same cloud computer at the same time, both models might try to use the same temp folder (like HMVDB1). Renaming temp folders to include t...
Andrew Fugal almost 6 years ago in InfoWater Pro / Productivity 0 Will not implement

Split pipes using the InfoWater "Digitize Network" tool

The "Digitize Network" tool can be used to draw new pipes and junctions, but does not split existing pipes, even though you can snap to existing pipes and add a junction. This can cause confusion because it appears that the pipe has been split whe...
Colin Ricks almost 6 years ago in InfoWater Pro 1 Under consideration

Automatically autofit DB table column widths

No description provided
Colin Ricks almost 6 years ago in InfoWater Pro / Productivity 1 Gathering support