Allow underdrains to receive upstream flows from a pipe. Repair inflows to SuDS.

The SuDS nodes do not allow the inflows from an upstream pipe to connect directly to the underdrains. There are only options to connect them through no delays to subsurface areas (i.e. in bioretention nodes) or as a point inflow (i.e. filter drain...
Iwona Savas about 1 year ago in InfoDrainage 0 For Review

Channel library similar to pipe library

It is essential to add / create library for rectangular channels with different width such as 300mm, 450mm width. Currently infodrainage choose a default 600mm wide rectangular channel. It is essential to have options to set minimum width other th...
Guest over 2 years ago in InfoDrainage / Hydraulics 1 Gathering support

Sort Manhole Schedules in Numerical Order

Hello, It should be possible to sort Manhole Schedules in Numerical Order - currently the randomness has lead to many questions & queries from site which has a risk for setting out/construction errors. It should also be possible to add MH type...
Guest over 1 year ago in InfoDrainage / Reporting 0 For Review

Update Scenario Explorer terminology to match Run Manager

Modelers can use the "General" tab in the IWP Scenario Explorer to assign specific Report, Simulation and Time options to a scenario. To avoid confusion, the label shown in the Scenario Explorer should be changed to match the Run Manager.
Michael Kane over 1 year ago in InfoWater Pro / Other 0 Gathering support

Store MSX data in Data Sets that could be used in DB Editor and Scenario Management

Currently, all MSX data like Initial Quality and Quality Source data is stored in the MSX model itself, which makes scenario management for MSX models very tedious. It would be much more intuitive and efficient if MSX data was stored in Data Sets ...
Grant Clemens over 1 year ago in InfoWater Pro / Water Quality 1 Gathering support

Delete Vertex in Pipe

I would like to be able to remove vertices from a pipe. Currently, you can only move the vertices or redraw the pipe. This process takes a while on big models and makes the distribution network more complicated.
Guest 10 months ago in InfoWater Pro / Other 0 Gathering support

TR-20 Runoff Generation

Can ID incorporate this methodology? MA department of Env Protection will be requiring this for their calculations.
Jess Ewing about 2 years ago in InfoDrainage / Hydrology 1 Gathering support

Add (change template) inlet from template to a junction without erasing the part family for the existing object

For example, in a model exported from Civil 3D, HEC-22 inlets need to be added to 100s of structures. The workflow is: 1. Create an Object Template for the HEC-22 inlet2. Right click each structure and change template to add a HEC-22 inlet The pro...
Daniel'le DeVoss about 1 year ago in InfoDrainage / Hydraulics 2 For Review

Plan View Annotation - Choose no. decimal places on pipe gradient value etc.

Displaying pipe gradients on plan (from Display Settings), which can be exported to CAD, is a very useful feature. However, when displaying pipe gradients, in the form 1: X, the X value is shown to 2 decimal places by default. It would be really u...
Dara Magee about 1 year ago in InfoDrainage / Visualization 0 For Review

Setting Out information for Swales

It seems I am unable to export proper 3D setting out data in the form of feature lines or 3D polylines for the base / top level of swales. I have designed several swales with a 1:200 gradient, but the export into C3D does not take into account the...