Skip to Main Content
Autodesk
ADD A NEW IDEA

All ideas

Showing 1373 of 1373

Import 12da Drainage Design strings and attributes to InfoWorks ICM to migrate drainage designs

No description provided
Guest almost 6 years ago in InfoWorks ICM / Import data 0 Gathering support

Create preset 2D inflow equation

Similar to inlet capacity, have the ability to create 2D inflow equations relative to inlet size and control depending on weir or orifice curves. This will allow the user to increase or change 2D inflow control easier and more standardized.
Guest almost 6 years ago in InfoWorks ICM / Hydraulics 1 Gathering support

Loading bars for large 2d TIN results.

Vissible loading progress for loading large or TIN modelling results.
Guest almost 6 years ago in InfoWorks ICM / Productivity / Terrain 0 Gathering support

colour labels based on flags

Make it possible to colour the labels based on the flags associated with the displayed field values.
Richard de Koning almost 6 years ago in InfoWorks ICM / Labels / Visualization 0 Gathering support

Interface Utility export efficiency

Can I make a suggestion regarding the InterfaceUtils.exe utility? Seeing that we are now dealing with considerably more rainfall data associated with ARR2016/2019 rainfall & temporal patterns, can Innovyze (or whoever created the abovementione...
Guest almost 6 years ago in Other Product Ideas / Storm, Sewer, Flood Modeling 0 Gathering support

Update fields by SQL that reference files other than loaded GIS tables ie CSV

Be able to update fields with data from external tables that don't reference primary InfoAsset fields ie Asset_ID, ID. Current SQL updates relly on input data being geocoded and user applying a spatial proximity. eg updating user_text_1 with vau...
Richard Robinson almost 6 years ago in Other Product Ideas / Asset Management 0 For Review

Add multiple rows to the InfoWater "Rule Header" DB table

In the "Pipe Control" or "Node Control" DB tables, I can insert or append multiple rows at once. In the "Rule Header" DB table, I can only insert or append one row at a time, and each row must have an ID. Please make the behavior of this table co...
Colin Ricks almost 3 years ago in InfoWater Pro 0 Under consideration

Add username to temp folder names to allow multiple users to model on the same cloud computer at the same time

Could InfoWater/InfoSWMM change how they name temp folders? Right now, if two users initialize a model on the same cloud computer at the same time, both models might try to use the same temp folder (like HMVDB1). Renaming temp folders to include t...
Andrew Fugal almost 6 years ago in InfoWater Pro / Productivity 0 Will not implement

Split pipes using the InfoWater "Digitize Network" tool

The "Digitize Network" tool can be used to draw new pipes and junctions, but does not split existing pipes, even though you can snap to existing pipes and add a junction. This can cause confusion because it appears that the pipe has been split whe...
Colin Ricks almost 6 years ago in InfoWater Pro 1 Under consideration

Automatically autofit DB table column widths

No description provided
Colin Ricks almost 6 years ago in InfoWater Pro / Productivity 1 Gathering support