Showing 264 of 1372

Convert connections to bypass connections

There should be an easier way to convert connections to bypass connections. Currently a connection needs to be deleted and recreated as a bypass. Having a right click option on a connection to convert it to a bypass would be ideal.
Guest 11 months ago in InfoDrainage / Hydraulics 0 For Review

Linear Drainage 2D conduit branch

In complex drainage systems, open channels may culvert in the middle or branch in two directions; it is useful to be able to branch into multiple pipes when modelling open channels in LD2D.
Yota Machii 12 months ago in InfoWorks ICM / Network 1 Under consideration

Add Snowmelt to InfoDrainage

The addition of SWMM5 snowmelt will make it easier to model LID's in North America which has a lot of snowfall in Canada and the northern USA. Snowmelt can be a significant source of water annually to a LID or SuDS.
ROBERT DICKENSON over 2 years ago in InfoDrainage / Hydrology 1 Under consideration

closed pipe

One of the nice features of WSPro is the ability to simply close a pipe. This would come in very handy in ICM as well, as this would allow for some very cool what if analyses and makes it possible to keep a pipe in the network (for visualization) ...
Marcel Glasbergen over 2 years ago in InfoWorks ICM / InfoWorks 2 Gathering support

Allow "Notes" for the "base" scenario, via the "Manage scenarios" dialogue

In the "Manage scenarios" dialogue, you can add helpful notes for each scenario, to explain what the scenario is representing. However, you cannot add notes for the base. It would be very helpful if you could add notes, as it is not always obvious...
Jason Kulsdom about 2 years ago in InfoWorks ICM / Scenario 0 Gathering support

Realistic Flow in SuDS structures

Realistic flow through bioretention, permeable paving and other SuDS within hydraulic models.
Guest about 3 years ago in InfoDrainage 0 Gathering support

Exceedance Level in Infodrainage

It would be good to have an option in underground stormwater controls to have a separate option for exceedance level and Ground Level By taking the exceedance level as GL, it makes the Long sections look distorted when in reality it is common for...
Guest about 3 years ago in InfoDrainage 1 Already exists

InfoDrainage - Permeable Paving

It would be useful to have a central granular conveyance trench beneath permeable paving to avoid the need for overly deep sub base beneath the road / drive.
Guest about 3 years ago in InfoDrainage 1 Already exists

Import EPASWMM5 Files

Importing EPASWMM5 files for US users would help to streamline the transition from SSA (you can export to SWMM5 from SSA)
Guest about 3 years ago in InfoDrainage 2 Under consideration

InfoDrainage - Split subcatchments option for Laurenson runoff routing method

It is industry best practice to split up the subcatchments in a model into their pervious and impervious areas when adopting the Laurenson (or RAFTS) runoff routing method ie U = 2 and U = 0. The current workflow to achieve this is to setup the mo...
Guest about 3 years ago in InfoDrainage 1 Under consideration