Option to "remember my choice" on the Query Set Cache pop-up

The pop-up asking whether to use the cache or re-run Query Sets every time you switch scenarios can get annoying. It would be nice to have a checkbox that says "always re-run queries" or something to that effect so that this pop-up can be suppressed.
Grant Clemens about 2 months ago in InfoWater Pro / Productivity 0 For Review

Provide Velocity Constraint in Multi-Fireflow

Provide the ability to limit velocity for the multi-fireflow run option. Presently only the Fireflow run option offers a max velocity constraint capability; the Multi-Fireflow run option does not have a max velocity feature.
Guest 11 months ago in InfoWater Pro / Engine 0 Under consideration

InfoSurge constant reporting interval

Often, different InfoSurge runs report results at different intervals, even though the simulation duration is the same. This makes it difficult to do comparisons of results. Please allow the user to set a report timestep like you can with a standa...
Colin Ricks 3 months ago in InfoWater Pro / Productivity 0 For Review

Create an RTC field within object properties in ICM

Currently in order to establish where & how RTC's are influencing a network, you are required to open the RTC editor window / expand each individual RTC to see all the details & cross reference any object ID's to see if it may be affecting...
Shaun Vial over 2 years ago in InfoWorks ICM / RTC 1 Gathering support

Ability to use variables in range RTC rules

For RTC range rules, we want to be able to use variables instead of constant values for the minimum and maximum values.
Guest almost 3 years ago in InfoWorks ICM / RTC 0 Gathering support

Provide InfoWater Pro integration with Civil 3D

Engineers and designers using Civil 3D for water distribution system design need to be able to verify the hydraulic adequacy of their designs quickly and efficiently in InfoWater Pro. There is currently no means by which to exchange Pressure Netwo...
Michael Kane almost 2 years ago in InfoWater Pro / Data Exchange 1 Under consideration

Batch Multi Fire Flow

I want the ability to model many different cases of multi-fire flow in parallel. This is important because I have many areas that require fire flow that is greater than what a single hydrant and later can achieve. Performing this manually for each...
Nathan Gerdts about 2 months ago in InfoWater Pro / Automation 0 Gathering support

Increase RTC Comment Length and Configuration

Currently RTC Comments are limited to 69 characters and only appear within a single box that you need to scroll horizontally to read. Please allow comments to be much larger and have multi-line format so we can add useful comments and explanations...
Dave White about 1 year ago in InfoWorks ICM / RTC 1 Under consideration

VSP Control based on Tank Head/Level

Currently you can only use Junction Pressure setpoints or Pump Flow setpoints in the VSP Control dialogue. It would be helpful to be able to use a Tank Level/Head setpoint to adjust the pump speed as well. This is possible in competitor products l...
Grant Clemens over 2 years ago in InfoWater Pro / Operational Modeling 3 Under consideration

Steady state simulations for different times or for average demand

Steady state simulations are useful for 1) evaluating an initial or simplified version of a model (for example with average demands) or 2) evaluating a specific condition (like maximum demand, etc.) without much complexity. If your model is alread...
Felipe Hernandez 4 months ago in InfoWater Pro / Engine 0 Gathering support