Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

Hydraulics

Showing 32

Vary infiltration with depth

Cannot currently use the software for deisgn of borehole soakaways. By their very nature they wil have varying infiltration rates. Usually the infiltration is at greatest depth and no way of modelling with correct head in borehole.
Guest about 1 year ago in InfoDrainage / Hydraulics 1 For Review

Add (change template) inlet from template to a junction without erasing the part family for the existing object

For example, in a model exported from Civil 3D, HEC-22 inlets need to be added to 100s of structures. The workflow is: 1. Create an Object Template for the HEC-22 inlet2. Right click each structure and change template to add a HEC-22 inlet The pro...
Daniel'le DeVoss about 1 year ago in InfoDrainage / Hydraulics 2 For Review

Add ability to create custom channel as underdrain (not just pipe)

Currently, you can only chose a pipe or multiple pipes as the underdrain within various features (infiltration trench, dry swale etc.). It would be great if a custom channel (section) could be used so an infiltration trench could be used to model ...
Oliver Dodd over 1 year ago in InfoDrainage / Hydraulics 0 For Review

Convert connections to bypass connections

There should be an easier way to convert connections to bypass connections. Currently a connection needs to be deleted and recreated as a bypass. Having a right click option on a connection to convert it to a bypass would be ideal.
Guest about 1 year ago in InfoDrainage / Hydraulics 0 For Review

Better hydraulic representation of flow in permeable paving

Flow through permeable paving does not occur as one would expect. Is greatly affected by the shape and direction the paving is drawn in InfoDrainage. When drawing an irregular shape the hydraulic grade lines appear incorrect, with flow all at one ...
Guest over 1 year ago in InfoDrainage / Hydraulics 0 For Review

Hybrid gravel and crate soakaway option

We would like a Stormwater control (soakaway) feature that allows for a narrow gravel trench below a crate layer within the same soakaway, we have tried modelling as two separate features but the interaction between the two systems isn't accurate ...
Mark Jennings 9 months ago in InfoDrainage / Hydraulics 0 For Review

Outfall Elevation Curve Time Series

Please add the ability to input decimal places for the Time in the Outfall Elevation Curves. Currently InfoDrainage only accepts whole numbers.
Guest 9 months ago in InfoDrainage / Hydraulics 0 For Review

Limit the chamber sizing calculator to 200 chambers

The chamber size calculator will add any number of chambers necessary, however, the model will not validate if the number of chambers exceeds 200. It would be better to not allow the calculator to exceed the validation limit.
Daniel'le DeVoss over 1 year ago in InfoDrainage / Hydraulics 0 For Review

Increase the limit of Chambers allowed

Currently in the 2025.2 version I am running, the number of Chambers for subsurface storage/detention allowed is 200. The sizing calculator says I need more and wouldn't validate the model. Would be nice to have a higher limit.
Bryan Forrest over 1 year ago in InfoDrainage / Hydraulics 0 For Review

Apply direct inflows to permeable paving

There should be a way of applying the inflow that the paving receives directly (i.e. the rain that falls onto it) to produce a more accurate simulation of the rainfall. This direct rainfall isn't a lateral or point inflow, and being forced to mode...
Craig Bobbett about 1 year ago in InfoDrainage / Hydraulics 0 For Review