Vary infiltration with depth

Cannot currently use the software for deisgn of borehole soakaways. By their very nature they wil have varying infiltration rates. Usually the infiltration is at greatest depth and no way of modelling with correct head in borehole.
Guest 6 months ago in InfoDrainage / Hydraulics 1 For Review

Add ability to create custom channel as underdrain (not just pipe)

Currently, you can only chose a pipe or multiple pipes as the underdrain within various features (infiltration trench, dry swale etc.). It would be great if a custom channel (section) could be used so an infiltration trench could be used to model ...
Oliver Dodd 9 months ago in InfoDrainage / Hydraulics 0 For Review

Need more inlet options

SSA has numerous inlet manufacturers and jurisdictions, including Caltrans, FDOT, Neenah, etc. These would be beneficial to have in InfoDrainage, including East Jordan inlets. Additionally, have depth vs flow curve option would be helpful as well.
Guest 12 months ago in InfoDrainage / Hydraulics 0 For Review

Convert connections to bypass connections

There should be an easier way to convert connections to bypass connections. Currently a connection needs to be deleted and recreated as a bypass. Having a right click option on a connection to convert it to a bypass would be ideal.
Guest 7 months ago in InfoDrainage / Hydraulics 0 For Review

Better hydraulic representation of flow in permeable paving

Flow through permeable paving does not occur as one would expect. Is greatly affected by the shape and direction the paving is drawn in InfoDrainage. When drawing an irregular shape the hydraulic grade lines appear incorrect, with flow all at one ...
Guest 9 months ago in InfoDrainage / Hydraulics 0 For Review

Apply direct inflows to permeable paving

There should be a way of applying the inflow that the paving receives directly (i.e. the rain that falls onto it) to produce a more accurate simulation of the rainfall. This direct rainfall isn't a lateral or point inflow, and being forced to mode...
Craig Bobbett 5 months ago in InfoDrainage / Hydraulics 0 For Review

Limit the chamber sizing calculator to 200 chambers

The chamber size calculator will add any number of chambers necessary, however, the model will not validate if the number of chambers exceeds 200. It would be better to not allow the calculator to exceed the validation limit.
Daniel'le DeVoss 10 months ago in InfoDrainage / Hydraulics 0 For Review

Increase the limit of Chambers allowed

Currently in the 2025.2 version I am running, the number of Chambers for subsurface storage/detention allowed is 200. The sizing calculator says I need more and wouldn't validate the model. Would be nice to have a higher limit.
Bryan Forrest 10 months ago in InfoDrainage / Hydraulics 0 For Review

Robust pond editor

Add options for complex pond shapes and items. Many municipalities now require items like latorial shelves, forebays, baffles, etc. these items do influence the detention time in the pond and can have effects on staging. While the size items can b...
Corey Balenger 9 months ago in InfoDrainage / Hydraulics 0 For Review

Orifice and Grate options - Outlet Control Structure

I suggest incorporating advanced features for modeling orifices and grates. Specifically, the following modifications would be beneficial: Orientation Settings: Introduce options to define the orientation of orifices and grates, allowing users to ...
Guest 12 months ago in InfoDrainage / Hydraulics 0 For Review