Option to remove the additional storage automatically added in geocellular systems

When designing a cellular soakaway, infodrainage automatically assumes a 1m2 plan area chamber between tank soffit and exceedance level (which would have been specified as ground level). In other structures you can specify freeboard and exceedance...
Guest over 1 year ago in InfoDrainage / Hydraulics 3 For Review

Incorporate the ability to create custom grate inlets. Currently InfoDrainage only allows for HEC22 defined inlet grate types to be used.

Some municipalities across New Zealand and other parts of the world require designers to use specified inlet grate types with defined inlet efficiency curves. There are two ways in which the custom inlet grate type this can be incorporated into In...
Quinton Botha about 1 year ago in InfoDrainage / Hydraulics 2 For Review

Non-circular pipes

Please add non-circular pipes to InfoDrainage, similar to those available SSA. These need the ability to connect to manholes at either end at a minimum, but the option to be culverted as well is welcomed.
Guest about 1 year ago in InfoDrainage / Hydraulics 1 For Review

Liquid filled/Flooded drainage network

Liquid filled/Flooded drainage network- the system should be required to design flooded drainage network i.e. drainage pipe should be always filled with liquid for entire length up to the discharge point. Like a surcharge up to manhole cover (liqu...
Guest over 1 year ago in InfoDrainage / Hydraulics 0 For Review

Button: Apply to all phases

To each of the build screens, next to "apply", add another button, "apply to all phases". This would save a lot of time when making tweaks to models for which more than one phase is being run (which is most models)
Guest over 1 year ago in InfoDrainage / Hydraulics 0 For Review

Weir coefficients

Expand the allowable range of weir discharge coefficients in InfoDrainage and provide an optional depth–coefficient user defined table to improve modeling flexibility and accuracy. Weir discharge coefficients (English units) typically range betwee...
Guest 8 months ago in InfoDrainage / Hydraulics 0 For Review

Need more inlet options

SSA has numerous inlet manufacturers and jurisdictions, including Caltrans, FDOT, Neenah, etc. These would be beneficial to have in InfoDrainage, including East Jordan inlets. Additionally, have depth vs flow curve option would be helpful as well.
Guest over 1 year ago in InfoDrainage / Hydraulics 0 For Review

Multiple fixed tailwater elevations

Currently, the software allows users to set only one fixed tailwater elevation per outlet. However, users need the ability to set different fixed tailwater elevations for different storm events (e.g., 10-year, 25-year, 100-year storms).
Guest about 1 year ago in InfoDrainage / Hydraulics 0 For Review

Add a storage structure feature for channel drains

Add a storage structure feature for channel drains (e.g. channel, slot drain, kerb drain) so that these features can be presented as storage and not only conveyance (by modelling a custom section) and so that catchments can be connected as a sheet...
Oliver Dodd over 1 year ago in InfoDrainage / Hydraulics 0 For Review

Show preliminary sizing estimated flow depth in profile view.

The proportional depth is given in the Network Design Report but not shown in the long sections. This is a very useful feature to allow quick checking of throttling or spare capacity in the network.
Matthew Johnson over 1 year ago in InfoDrainage / Hydraulics 0 For Review