Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

Ideas

Showing 595 of 1442

Need additional Timestep function for "Between episodes" of "Simulation runoff only"

It needs creating a new Timestep function in ICM Run window that allows setting up timestep for "Simulation runoff only" for the "Between episodes" separately with "Timestep (s)" in Run window. This new function saves a lot of running time when th...
Guest over 3 years ago in InfoWorks ICM / Events / Simulations 0 Gathering support

Interpolation of levels

It happens too often that while merging different models, you suddenly need a different timestep for your level-file. The only way to do this now, is remake your level completely. It would be better to (when changing the timestep of your level) IC...
Guest about 6 years ago in InfoWorks ICM / Events / Productivity 1 Gathering support

Initial condition 1D setting value

For Initial Conditions 1D, InfoWorks ICM seems to specify 1) initial level(m AD) and inflow values at nodes for Nodes grid, 2) and initial depth (m) and flow values along the river reach for River Reaches grid. For river reaches grid, as an initia...
Guest almost 2 years ago in InfoWorks ICM / InfoWorks 1 Will not implement

Modelling of mud and other non-Newtonian flows

We've a lot of work at the moment modelling the failure of tailings dams. Tailings dams typically have material that acts in a non-Newtonian manner. To effectively model these sorts of fluids would require the inclusion of additional fluid propert...
Richard Body about 6 years ago in InfoWorks ICM / Hydraulics / Sediment 0 Gathering support

ICM - HEC-22 Combination Inlet for continuous grade inlets

Currently ICM has 6 FWHA Gully Inlet types: ContCo Continuous Curb Opening ContG Continuous Grate SagC Sag Combination SagCO Sag Curb Opening SagG Sag Grate and UPC Grate A commonly used Inlet type (particularly in QLD Australia) that is missing ...
Guest over 3 years ago in InfoWorks ICM / Hydraulics 0 Gathering support

Correct calculation of volume within storage node when using porosity

Currently when a porosity value is applied to a storage node, the porosity is only applied for storage array entries which are below ground level. Storage array entries above ground level are assumed to have a porosity of 100%. Between the highest...
Lizzie over 4 years ago in InfoWorks ICM / Hydraulics 1 Gathering support

add Xylem Nexicom Smart System to control pumps as a modelling option

we are increasing using Xylem Nexicom Smart System to control pumps in pumping stations across Scotland. This smart control system includes an number of functions such as Energy Minimizer and Sup and pipe cleaning . Scottish Water has found diffic...
francisco simon 11 months ago in InfoWorks ICM / RTC 1 Will not implement

Attribute table copy function

A better copy function between networks might be usefull: e.g. Also copy the 'link head discharge' or 'conduit shape geometry' tables when copying a link from one network to an other. Or at least a popup allowing you to select which lists to copy ...
Guest over 5 years ago in InfoWorks ICM / Productivity 0 Gathering support

Call the 'Total storage calculation' function from a ruby script and write the output into a csv-file

It would be a great feature to call the 'Total storage calculation' function from a ruby script and write the output into a csv-file. If it is not possible to call the build-In function from ruby, it would also help to call the 'storage calculat...
Guest over 4 years ago in InfoWorks ICM / API / Exchange / Export Data / Ponds/Storage 0 Gathering support

Add a modelling confidence field into the User Defined Flags

This could simply be an additional free text field in the "User Defined Flags" window labelled "confidence" OR the user is able to define their own but they are limited to 5-7 options. The benefit is that when users pick up a model they better u...
Alex Grist over 6 years ago in InfoWorks ICM / Flags 0 Gathering support