Better hydraulic representation of flow in permeable paving

Flow through permeable paving does not occur as one would expect. Is greatly affected by the shape and direction the paving is drawn in InfoDrainage. When drawing an irregular shape the hydraulic grade lines appear incorrect, with flow all at one ...
Guest about 1 year ago in InfoDrainage / Hydraulics 0 For Review

Simulation Health Improvements

In certain instances, the suggestions provided in "Simulation Health: The results indicate flow continuity issues, even when the shortest time step is already selected in InfoDrainage" may not resolve the problem. This could be addressed by incorp...
Guest over 1 year ago in InfoDrainage / Hydraulics 1 In progress

Add Gravel Pit to Soakaway Design Tool

As a former MicroDrainage user, I'm struggling to model soakaways in InfoDrainage, as InfoDrainage does not account for storage volume within the gravel filter media that surrounds the soakaway. The gravel pit also provides larger area of infiltra...
Aleks Persins over 1 year ago in InfoDrainage / Hydraulics 5 Already exists

Option to compare Simulations of different time ranges superimposed on one graph [IWLive]

As an operator, I want to compare today's forecasted operations with different days in the past so I can see alternative ways how similar situations played out and make decisions with confidence. IWLive already offers functionality to compare two ...
Nathan Gerdts 7 months ago in InfoWorks WS Pro / Operations 0 For Review

Limit the chamber sizing calculator to 200 chambers

The chamber size calculator will add any number of chambers necessary, however, the model will not validate if the number of chambers exceeds 200. It would be better to not allow the calculator to exceed the validation limit.
Daniel'le DeVoss about 1 year ago in InfoDrainage / Hydraulics 0 For Review

Increase the limit of Chambers allowed

Currently in the 2025.2 version I am running, the number of Chambers for subsurface storage/detention allowed is 200. The sizing calculator says I need more and wouldn't validate the model. Would be nice to have a higher limit.
Bryan Forrest about 1 year ago in InfoDrainage / Hydraulics 0 For Review

Distribution Network Energy Optimization

Minimize the pumping costs of water distribution while satisfying water demand and operational constraints (water levels, pressure, pump station capacities, future maintenance operations, etc).
Nathan Gerdts over 1 year ago in InfoWorks WS Pro / Operations 0 Gathering support

Apply direct inflows to permeable paving

There should be a way of applying the inflow that the paving receives directly (i.e. the rain that falls onto it) to produce a more accurate simulation of the rainfall. This direct rainfall isn't a lateral or point inflow, and being forced to mode...
Craig Bobbett 10 months ago in InfoDrainage / Hydraulics 0 For Review

Infiltration Trench using BRE DIGEST 365 method

The software needs to support for designing Infiltration trench method by using “BRE DIGEST 365”. I have checked the comparison between Infodrainage analysis Vs BRE digest 365 (manual calculation) and the results are not matching. Most of the proj...
Guest almost 2 years ago in InfoDrainage / Hydraulics 8 Gathering support

Swale with pipe under connected by manholes

Could not model real-life scenario where the pipe was under as conveyance for lesser events and raised via vented manholes into the swale above. Need integrated solution and was unable to model both and connect via manholes.
Guest almost 2 years ago in InfoDrainage / Hydraulics 1 Already exists