Costs that vary based on different parameters (Material, size, buried depth, etc)

Costs vary based on different parameters as it is not the same to replace a 6in pipe vs a 12 in pipe. Pipes that are buried deeper are also more expensive.
Martha Nunez about 2 years ago in Info360 Asset / Rehab actions & cost 0 In progress

Pump Station Operation Narrative

Would like the ability to add a pump station narrative. For example, a station may have several pumps and varying set points, however those set points do not relate to a specific pump. The station may operate where once the first set point is reac...
Dave White about 1 year ago in InfoWorks ICM / Pumps 0 For Review

Pump Station Modelling

Infoworks ICM pump station modelling principle is very basic, adding a pump between two nodes is highly hypothetical. There is no way to add pump station head losses. I would like to suggest incorporating pump station modelling (for Rotodynamic pu...
Guest over 3 years ago in InfoWorks ICM / Hydraulics / Pumps 1 Gathering support

Inlet pump

We are mode and more incorporating surface water systems in our ICM models and part of those systems are inlet pumps that respond to the downstream levels instead of the upstream levels. Up until now, the only way to achieve this is by creating an...
Marcel Glasbergen over 2 years ago in InfoWorks ICM / Pumps / RTC 0 Gathering support

Have a costs library available under the rehab actions page

With this functionality, users could have an estimated cost for all assets in their system as soon as they run the rehab tree. This eliminates additional data input and management making the cost reporting much more efficient specially for those u...
Martha Nunez about 2 years ago in Info360 Asset / Rehab actions & cost 0 Gathering support

Add SWMM5 Ideal Pump to InfoWorks ICM

Does InfoWorks ICM have an equivalent to an ideal pump in SWMM which pumps whatever is entering the SPS out of the SPS? It would be a good feature to include into infoworks as I needed to play around a bit to get it. I found I had to add line 2 ...
Guest about 6 years ago in InfoWorks ICM / Hydraulics / Pumps 1 Gathering support

Support for LACP v7 and v8

This is a request for support for LACP CCTV Management in Info360 Asset.
Martha Nunez almost 3 years ago in Info360 Asset / CCTV Standards (e.g. PACP) / Rehab actions & cost 1 On roadmap

Calculation of Pump Power in ICM

A pump curve and energy/efficiency curve can be input into the software however there is no way to output the energy used by the pump. South Gippsland Water were keen on understanding whether ICM could do this to report their energy efficiency bas...
Ann Pugh almost 5 years ago in InfoWorks ICM / Pumps 0 Gathering support

I would like the option to model pump station that operate using VFDs.

I would like to be able to enter the full and reduced speed pump curves for each pump station that is controlled by variable frequency drives. In addition, I would need the set point or control that causes the pumps to ramp up to full speed.
Guest over 5 years ago in InfoWorks ICM / Pumps 0 Gathering support

Change Variable Speed Pumps Image

The image for Variable Speed Pumps under the "Other Special Diversion Examples" section is likely wrong. Looks like it is a copy of the image for Pump discharge pipes. Would be great if you could update with the right image! Thanks
Guest over 4 years ago in InfoWorks ICM / Pumps 0 Gathering support