Skip to Main Content
Autodesk

Addition of error message

When creating a mesh for the 2D zone of Clip meshing, if a single infiltration zone straddles multiple 2D zones, the meshing process succeeds, but an E2225 message occurs in validation. I understand that this message occurs because the infiltration zone object is originally intended to assign multiple permeabilities within a single 2D zone.

However, the E2225 message states, "Infiltration zone (2D) <infiltration zone id> has been added since meshing was performed." The cause or this issue is that a single infiltration zone straddles multiple 2D zones, not that the infiltration zone was added after meshing. Therefore, users cannot understand the cause. Could you change the error message displayed in validation to something more understandable, such as "Infiltration zone (2D) A is set across multiple 2D zones"?

  • Attach files
      Drop here to upload