Guidance (including examples) and solver assumptions in ICM help

Could the ICM help be refreshed/updated and include more examples and/or details of the physics / assumptions / settings used by the simulation solver? Some examples below - Orifice control – Technical paper “Orifices” (June 2005) is not available anymore. Could this be updated and re-introduced as it was valuable guidance - Head / discharge curves – “The overall relationship between discharge and head in both directions is represented as a data table of up to 15 discharge values at head values equally spaced by a specified increment.” It seems that more than 15 values can be used and not necessarily equally spaced
  • ADMIN RESPONSE
    Apr 24, 2023
    The orifice control paper is an older CS/SD paper that was not included in the InfoWorks ICM.  We can look into updating that for InfoWorks ICM. The Head/Discharge curve statement appears to be a remnant of HydroWorks.  InfoWorks can have an arbitrary number of entries in a head-discharge curve and they do not need to be evenly spaced by head.