Allow a sensor (virtual or physical) to be selected as the threshold value

It would be useful to compare a sensor value against another sensor value to create an alert.
Brad Thompson over 2 years ago in Info360 Insight / Alerts 0 Gathering support

Max or Min Flow values should not depend on the pipe direction. i.e. the value being positive or negative depend on the pipe direction

Currently, if the flow direction through the pipe is opposite to the direction of the pipe drawn it shows as a negative flow value. So if the flow goes both direction during the run, smaller positive value shows as the maximum flow and larger nega...
Guest over 5 years ago in InfoWorks WS Pro / Other 0 Gathering support

The ability to create multiple Selection Lists at once

I am currently working on a model with a large number of DMAs. This means I have to select each specific area, and save this as a selection list - so I can easily identify areas in the future. This is a very time consuming task, and the ability to...
Sam Bonnington almost 3 years ago in InfoWorks WS Pro / Automation 1 Gathering support

To be able to graph refill/depletion rate and/or survival time on reservoirs and towers

in WS Pro
Guest over 5 years ago in InfoWorks WS Pro 1 Gathering support

WS Pro to allow for maxconc at node/hydrant

No description provided
Guest over 5 years ago in InfoWorks WS Pro / Water Quality 1 Gathering support

A simple way to straighten short links to display symbols more clearly

When using the "Expand Short Links" option I find that the expanded links will inherit some geometric points from the adjacent links, and hence symbols for valves, meters etc may not display too well if adjacent to a pipe bend. It would be useful ...
Owen Lewis almost 6 years ago in InfoWorks WS Pro / Other 1 Gathering support

Populate Pump run schedule based on telemetry data in WS Pro

As a planning modeler calibrating within WS Pro, I want to use the "Load from Live Data" tool on pumps in Plan mode to populate the Control Data timeseries profile based on a data stream of 1's and 0's indicating on/off. While this is already avai...
Guest over 4 years ago in InfoWorks WS Pro / Telemetry 0 Gathering support

WS Pro control should be based on current time step

Add option in WS Pro so that control status of objects is controlled by the flow solution in the current time step, not the previous time step. The way WS Pro currently works, with the control based on the previous TS often results in pump on/off ...
Haddon Smith almost 5 years ago in InfoWorks WS Pro / Engine 0 Gathering support

HGL levels without nodes on links(pipes)

There is a scenario in which the water mains reach the top of a hill(pumping to reach the top) and then the water just drives by gravity to a storage tank. Instead of having multiple nodes in between to give the exact hydraulic grade levels, an op...
Rajesh Gaddam almost 2 years ago in InfoWorks WS Pro / Productivity 2 Gathering support

Integrate the GMR runs to database and IWLive export style

Integrate the GMR runs to database and IWLive export style:1- Get data from database as initial values.2- Export GMR results to external database.
Mahmoud Abualrub almost 2 years ago in InfoWorks WS Pro / Data Exchange 2 Gathering support