Be able to change the background colour

In InfoWorks the background colour for the GeoPlan is white - it would be beneficial to change this colour to the users choice to make particular features stand-out more clearly in the GeoPlan view
Guest about 6 years ago in InfoWorks WS Pro 0 Gathering support

Initial condition 1D setting value

For Initial Conditions 1D, InfoWorks ICM seems to specify 1) initial level(m AD) and inflow values at nodes for Nodes grid, 2) and initial depth (m) and flow values along the river reach for River Reaches grid. For river reaches grid, as an initia...
Guest almost 2 years ago in InfoWorks ICM / InfoWorks 1 Will not implement

Support variable speed in live data

Variable speed is now an unsupported attribute in live data.
Evi Loozen about 6 years ago in InfoWorks WS Pro / Telemetry 2 Under consideration

Modelling of mud and other non-Newtonian flows

We've a lot of work at the moment modelling the failure of tailings dams. Tailings dams typically have material that acts in a non-Newtonian manner. To effectively model these sorts of fluids would require the inclusion of additional fluid propert...
Richard Body about 6 years ago in InfoWorks ICM / Hydraulics / Sediment 0 Gathering support

ICM - HEC-22 Combination Inlet for continuous grade inlets

Currently ICM has 6 FWHA Gully Inlet types: ContCo Continuous Curb Opening ContG Continuous Grate SagC Sag Combination SagCO Sag Curb Opening SagG Sag Grate and UPC Grate A commonly used Inlet type (particularly in QLD Australia) that is missing ...
Guest over 3 years ago in InfoWorks ICM / Hydraulics 0 Gathering support

Correct calculation of volume within storage node when using porosity

Currently when a porosity value is applied to a storage node, the porosity is only applied for storage array entries which are below ground level. Storage array entries above ground level are assumed to have a porosity of 100%. Between the highest...
Lizzie over 4 years ago in InfoWorks ICM / Hydraulics 1 Gathering support

Add tool to convert coordinates

Similar to "Convert flow units" and "Convert pressure units" under"Tools", it would be useful to have "Convert Coordinate Units". Coordinates in InfoWorks are meter/feet. Other websites like google maps uses decimal degree. It would be useful to h...
Mohammed Abdallah almost 2 years ago in InfoWorks WS Pro / Productivity 0 For Review

add Xylem Nexicom Smart System to control pumps as a modelling option

we are increasing using Xylem Nexicom Smart System to control pumps in pumping stations across Scotland. This smart control system includes an number of functions such as Energy Minimizer and Sup and pipe cleaning . Scottish Water has found diffic...
francisco simon 11 months ago in InfoWorks ICM / RTC 1 Will not implement

Integration with Lucity (Central Square)

Prioritized I360A action plan to be implemented and completed in CMMS - then once work is completed the equivalent work/project in I360A needs to be updated as complete. Different types of work orders for risk and rehab analysis, and for deteriora...
Martha Nunez over 2 years ago in Info360 Asset / Other 0 Gathering support

Network Schematic for interaction with InfoWorks WS Pro models

I want to interact with my distribution network in a simplified schematic view, which displays DMA's and important control objects like pump stations and reservoirs. Software should be able to update the schematic based on changes to network conne...
Guest over 4 years ago in InfoWorks WS Pro 1 Gathering support