Make the Software more integrated with GIS

it will be much of help if the software supports TiFF or GeoTiFF files imports to allow usage of rasters for importing the soil types and land use. also importing tiff files can used to import surfaces from DEM weather open source or taken by LiDa...
Guest 11 months ago in InfoDrainage / Hydrology 0 For Review

Right-click and respecify connection origin

Currently, we can right-click and respecify connection (and bypass connection) destinations. We need the ability to respecify origins as well, to avoid having to redraw connections.
Daniel'le DeVoss about 1 year ago in InfoDrainage / Hydrology 0 For Review

Allow underdrains to have a different slope to the SuDS feature

Allow a storage structure such as dry swale, bioretention area or infiltration trench to have a different slope to the underdrain. Currently the underdrain has to follow the slope of the feature, which is not a real life representation of how they...
Oliver Dodd over 1 year ago in InfoDrainage / Hydraulics 0 For Review

Aerial background mapping

Would it be possible to add aerial background mapping, such as with AutoCAD.
Matthew Johnson over 1 year ago in InfoDrainage / Visualization 1 For Review

Relative file paths for CAD data etc.

Would it be possible to use relative file paths for attached information, such as CAD data. A lot of work is done on fileshare sites e.g. SharePoint. If one person syncs the model and another opens it, all the linked data is lost as the global fil...
Matthew Johnson over 1 year ago in InfoDrainage / Data Exchange 0 For Review

Add max pipe flow to the pipe properties window

Max pipe flow (theoretical pipe full) is not listed in pipe properties, as it was previously in MicroDrainage. It was a useful feature.
Ian George 4 months ago in InfoDrainage / Productivity 0 For Review

Downstream pipes matching soffits/inverts

Currently when making changes in InfoDrainage the downstream pipes do not automatically adjust to the lowest incoming pipe. This means we have to manually adjust (and usually then lock) most pipes which is a downgrade from MicroDrainage.I understa...
Ian George 4 months ago in InfoDrainage 0 For Review

Chezy Formula option

It would be useful to have a direct input for Chezy coefficient as an alternative to mannings n as some regions need to use this as an input and report on this too - this would result in less workaround and data manipulation
matthew.piggott over 1 year ago in InfoDrainage / Hydraulics 0 For Review

Save phase results seperately

When working with multiple phases I would like to be able to run one phase (exclude all others from analysis) and have the results saved. Results should only be overwritten when a new run on the same phase is completed.
Andrew Komarnycky about 1 year ago in InfoDrainage / Productivity 0 For Review

Graphical editing in Longsection

Being able to manually drag pipes up/down and alter their gradient in the long section graphics, was an extremely efficient workflow in Microdrainage, especially when using min. pipe design levels to dictate land-raise FGLs. Can this function be c...