Skip to Main Content
Autodesk
ADD A NEW IDEA

InfoDrainage

Showing 67

Calculating and adding the Froude number to storm table output

Many municipalities and utilities want to maintain subcritical flow in the storm sewer system and avoid hydraulic jumps. The Froude number is used to establish subcritical vs. supercritical flow.
Guest 4 months ago in InfoDrainage / Reporting 2 For Review

show upstream and downstream cover depth for connections

MicroDrainage used to show this its useful for checking cover to pipes are correct
Matt Hare 4 months ago in InfoDrainage / Productivity 0 For Review

Liquid filled/Flooded drainage network

Liquid filled/Flooded drainage network- the system should be required to design flooded drainage network i.e. drainage pipe should be always filled with liquid for entire length up to the discharge point. Like a surcharge up to manhole cover (liqu...
Guest 5 months ago in InfoDrainage / Hydraulics 0 For Review

Add (change template) inlet from template to a junction without erasing the part family for the existing object

For example, in a model exported from Civil 3D, HEC-22 inlets need to be added to 100s of structures. The workflow is: 1. Create an Object Template for the HEC-22 inlet2. Right click each structure and change template to add a HEC-22 inlet The pro...
Daniel'le DeVoss about 2 months ago in InfoDrainage / Hydraulics 1 For Review

Order Junction & Connection Results Printout by Flowpath (to match the Model Printout)

Issue: When using the 'print' feature, if a flow path is selected, the model summary for junctions will show ALL connected pipes, in 'flow' order, which is very useful for presenting/understanding data. However, in the results tab for connections,...
Alex Purcell 9 months ago in InfoDrainage / Reporting 0 For Review

Non-circular pipes

Please add non-circular pipes to InfoDrainage, similar to those available SSA. These need the ability to connect to manholes at either end at a minimum, but the option to be culverted as well is welcomed.
Guest about 2 months ago in InfoDrainage / Hydraulics 1 For Review

Convert connections to bypass connections

There should be an easier way to convert connections to bypass connections. Currently a connection needs to be deleted and recreated as a bypass. Having a right click option on a connection to convert it to a bypass would be ideal.
Guest about 2 months ago in InfoDrainage / Hydraulics 0 For Review

Plan View Annotation - Choose no. decimal places on pipe gradient value etc.

Displaying pipe gradients on plan (from Display Settings), which can be exported to CAD, is a very useful feature. However, when displaying pipe gradients, in the form 1: X, the X value is shown to 2 decimal places by default. It would be really u...
Dara Magee about 2 months ago in InfoDrainage / Visualization 0 For Review

Permeable Pavement with varying depth

Please add an option to input the surface slope and formation level slope for the permeable pavements to represent the varying depth of storage below. This is one of the 3 options we use at steeper sites to provide adequate storage in permeable pa...
Dilraj KT 6 months ago in InfoDrainage / Hydraulics 0 For Review

Sort and collapse all option in flowpath Network Design Report

It would be useful to be able to ‘collapse all’ for branches in the Network Design Report. It would also be useful to be able to sort the connections (and junctions) in order of upstream→downstream or alpha/numeric. At the moment it seems rather a...
Matthew Johnson 5 months ago in InfoDrainage / Auditing / Reviewing 0 For Review