Chezy Formula option

It would be useful to have a direct input for Chezy coefficient as an alternative to mannings n as some regions need to use this as an input and report on this too - this would result in less workaround and data manipulation
matthew.piggott over 1 year ago in InfoDrainage / Hydraulics 0 For Review

Graphical editing in Longsection

Being able to manually drag pipes up/down and alter their gradient in the long section graphics, was an extremely efficient workflow in Microdrainage, especially when using min. pipe design levels to dictate land-raise FGLs. Can this function be c...
Guest about 1 year ago in InfoDrainage / Productivity 0 For Review

Save phase results seperately

When working with multiple phases I would like to be able to run one phase (exclude all others from analysis) and have the results saved. Results should only be overwritten when a new run on the same phase is completed.
Andrew Komarnycky about 1 year ago in InfoDrainage / Productivity 0 For Review

Video generation of InfoDrainage simulations

Requesting the ability for InfoDrainage to export simulations to .mp4 or .avi files for distribution and review. Right now, you can play the simulation in InfoDrainage, but need a screen capture software to record the results into the video for ex...
Tim Medearis 11 months ago in InfoDrainage / Reporting 1 For Review

Ability to look at multiple phases (surface and foul networks together) in 3D

Being able to view both surface and foul networks within MicroDrainage was always a very useful feature to visualise crossing points in the network and it doesn't look to have been included in InfoDrainage.
Henry Wilkinson 11 months ago in InfoDrainage / Productivity 1 For Review

show upstream and downstream cover depth for connections

MicroDrainage used to show this its useful for checking cover to pipes are correct
Matt Hare over 1 year ago in InfoDrainage / Productivity 0 For Review

Permeable Pavement with varying depth

Please add an option to input the surface slope and formation level slope for the permeable pavements to represent the varying depth of storage below. This is one of the 3 options we use at steeper sites to provide adequate storage in permeable pa...
Dilraj KT over 1 year ago in InfoDrainage / Hydraulics 0 For Review

Option to remove the additional storage automatically added in geocellular systems

When designing a cellular soakaway, infodrainage automatically assumes a 1m2 plan area chamber between tank soffit and exceedance level (which would have been specified as ground level). In other structures you can specify freeboard and exceedance...
Guest over 1 year ago in InfoDrainage / Hydraulics 3 For Review

Ability to change flow path in the profile view

It would be very convenient to be able to select a different flow path from within the long section (profile) view.
Matthew Johnson over 1 year ago in InfoDrainage / Auditing / Reviewing 0 For Review

Colour coding of connections and junctions

Can the functionality of colour coding pipes (by depth, diameter, flood status or user-choice) be added. This is very useful for checking models or recording changes, pipe condition, ownership etc.