Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

Ideas

Showing 144

Allow CCTV Inspections to be associated to a pipe/culvert when PLR and asset IDs match but no manhole IDs are provided in the CCTV inspection

Allow inspections to be imported WITHOUT (i.e. missing) manhole IDs but still provide the association to the asset via the PLR if a corresponding pipe asset has the same asset ID. In the situation where there are no manhole IDs provided then I360A...
Tony Andrews over 1 year ago in Info360 Asset 0 Gathering support

Modelling intermediate check dams and weirs in open channels including ponds ands swales

Currently, InfoDrainage only allows modeling of check dams or weirs at outlets. For open channels with multiple intermediate check dams, users must split the channel into sections, each with its own outfall defined. A more accurate feature allowin...
Dilraj KT over 2 years ago in InfoDrainage / Hydraulics 1 Gathering support

Provide Enhanced Manhole Schedule Details

It would be great to have the option of providing an additional level of customisable detail which could be configured on MH Schedules. As an example including practical details around the cover – contractors want to know and see more from a MH s...
Guest over 3 years ago in InfoDrainage 1 Gathering support

Comparison of total length of rehab methods vs total pipe length

Similar to 'Comparison of total length of defects vs total pipe length' however, rehab methods can be assigned to multiple defects. For example the rehab method 'lining' can be assigned to defect codes CC, CL, FM, etc. the total length of a rehab ...
Martha Nunez over 1 year ago in Info360 Asset 1 Gathering support

Attach reports (pdfs) to asset

We sometimes get inspection data in a pdf format and other times we may have a write up on the condition of the asset. It would be useful to attach this to the asset.
Lauren de Bude 8 months ago in Info360 Asset / Import / Upload 1 Gathering support

PACP v8 Compliance for InfoAsset Manager and Info360 Asset

Version 8 was released in early 2024. It includes pressure pipe assessment codes. This grading system would be a significant improvement to the PACP7 compliance which, while still popular, is 7 years old. NASSCO has sunset version 6, and no longer...
Tim Medearis almost 2 years ago in Info360 Asset / CCTV Standards (e.g. PACP) 2 Gathering support

Parcel Import to Catchment

It would be extremely helpful if InfoDrainage could import Civil 3D Parcels directly as catchment areas, similar to how it currently imports other CAD data (polylines). Parcels often represent drainage catchments, lots, or contributing areas in si...
Guest 6 months ago in InfoDrainage / Data Exchange 1 Gathering support

Retain company logo in Hard Copy Headings

Company logo/attached image currently disappears from Hard Copy Headings after closing and reopening InfoDrainage. Other headings are retained. The image should also be retained when the file is reopened.
Daniel'le DeVoss almost 2 years ago in InfoDrainage / Reporting 2 Gathering support

Cumulative Inflow Areas Against Junctions and Connections Results

In order to aid the quality assurance process that exists throughout drainage design, it would make life much simpler to have a cumulative contributing inflow area against junction summaries. Being able to sense check results with the contributing...
Guest 10 months ago in InfoDrainage / Reporting 2 Gathering support

Junction Loss

There need to be more options for calculating junction loss. Having values for entry and exit loss isn't enough. Recommend HEC-22 and AASHTO at a minimum.
Guest over 1 year ago in InfoDrainage / Hydraulics 2 Gathering support