Interpolation of levels

It happens too often that while merging different models, you suddenly need a different timestep for your level-file. The only way to do this now, is remake your level completely. It would be better to (when changing the timestep of your level) IC...
Guest almost 6 years ago in InfoWorks ICM / Events / Productivity 1 Gathering support

Play/Pause button

Current play and pause buttons (when viewing simulation results) are separate. I realise there are step buttons but if I want to start/stop quickly, whilst looking at the results instead of where the mouse is, then it's more convenient as a single...
Matthew Paul over 1 year ago in InfoWorks ICM / Productivity 0 Gathering support

CCTV inspections should have their own data grid

This request is for a dedicated data grid in which CCTV inspection hearder details should be viewable. Inspections can then be filtered, sorted etc. Even better if this data grid could be hooked up to a dedicated asset condition map integrated wit...
Tony Andrews over 1 year ago in Info360 Asset / Data Editing / Inspection & Media Management Workflows / Map visualization / Product workflows 0 Gathering support

Be able to change the background colour

In InfoWorks the background colour for the GeoPlan is white - it would be beneficial to change this colour to the users choice to make particular features stand-out more clearly in the GeoPlan view
Guest almost 6 years ago in InfoWorks WS Pro 0 Gathering support

add HL/1000 to graphs

When you create a graph object to graph data from objects for multiple simulations against each other, there is no option to add HL/1000 data. Everything else is there but HL/1000 is missing. Please add this to the list.
Ben Davies over 2 years ago in InfoWorks WS Pro / Other 0 Gathering support

Available flow capacity analysis with relative pressure drop tolerance

We want to evaluate how much additional demand flow can be pulled from each node independently, while ensuring that no node or customer in the system drops by more than 1 meter of minimum pressure.
Nathan Gerdts 10 months ago in InfoWorks WS Pro / Automation 0 Gathering support

ICM - HEC-22 Combination Inlet for continuous grade inlets

Currently ICM has 6 FWHA Gully Inlet types: ContCo Continuous Curb Opening ContG Continuous Grate SagC Sag Combination SagCO Sag Curb Opening SagG Sag Grate and UPC Grate A commonly used Inlet type (particularly in QLD Australia) that is missing ...
Guest over 3 years ago in InfoWorks ICM / Hydraulics 0 Gathering support

Storage area polygons

Storage nodes often represent detention basins or other locations with large areas. Pipes enter/leave from opposite sides. With the standard link/node configuration, one or more link will be mis-configured compared to the actual location. I have...
Guest about 5 years ago in Other Product Ideas / Storm, Sewer, Flood Modeling 2 Gathering support

Correct calculation of volume within storage node when using porosity

Currently when a porosity value is applied to a storage node, the porosity is only applied for storage array entries which are below ground level. Storage array entries above ground level are assumed to have a porosity of 100%. Between the highest...
Lizzie over 4 years ago in InfoWorks ICM / Hydraulics 1 Gathering support

ICM SWMM should show the Pipe Slope and Full Flow (PFC) on the Properties Dialog

While it might seem like a small detail, the ability to access the same properties on a Grid in ICM SWMM that were available in InfoSWMM can significantly enhance user experience. Many users request to see properties such as pipe slope and PFC val...
Robert Dickinson over 1 year ago in InfoWorks ICM / Grids 0 Gathering support