When Survey Length is Different than pipe length, do not give a warning unless it is larger than 5ft difference.

Many inspections end up with warnings when this very common issue comes up. Most of the time survey length and pipe length will be different because the GIS is not 100% perfect.
Guest almost 3 years ago in Info360 Asset / Inspection & Media Management Workflows 1 Gathering support

Info360 Asset support multi-sensor inspections

Examples include pipe penetrating radar, sonar, CCTV, LIDAR, side-scan etc. Read https://trenchlesstechnology.com/advancements-in-multi-sensor-inspection-technologies-for-large-diameter-sewers/ Vendors of equipment and software include: https://se...
Tony Andrews about 1 year ago in Info360 Asset / Inspection & Media Management Workflows 0 Gathering support

Add a "comments" or "notes" option to the 'Reject' status for Field Inspector users to know why Inspection was rejected

There is no way for the inspector to know what is supposed to be fixed.
Guest almost 3 years ago in Info360 Asset / Inspection & Media Management Workflows 1 Already exists

Edit Pump and Valve Curves in IWLive

IWLive is the perfect platform to examine how well valve and pump curves are simulating the actual behavior under a wide range of system conditions. If these could be modified in an incident run, it would save lots of time going back to WS to modi...
Guest over 5 years ago in InfoWorks WS Pro / Operations 0 Gathering support

Creation of the Pump element independent of its grouping in the Pumping Station as included in usual infrastructure catalogs (GIS)

Useful for maintaining the unique relationship between the elements of a supply network and the Infoworks model objects.
Juan Carlos Ortega over 2 years ago in InfoWorks WS Pro / Operations 2 Will not implement

Provide an Early Warning Notification on CCTV Inspections that will Indicate an Emergency Situation

Some defects or combination of defects in a sewer or stormwater condition or associated maintenance structure may constitute an emergency condition where service failure is likely with economic, environmental, public safety, public image, and/or p...
Tony Andrews almost 3 years ago in Info360 Asset / Inspection & Media Management Workflows / Inspections / Product workflows 0 For Review

I want more flexible shutdown runs

e.g.: I want to be able to evaluate shutdwon of pumping stations in 1 one run, now I have to create a seperate run for each pumping station. A workaround I use is closing links with a GRM config, but this only shuts down links for the whole simula...
Caroline Heylen almost 4 years ago in InfoWorks WS Pro / Operations 1 Under consideration

A simple way to get an upstream or downstream trace analysis for all objects (node or pipe)

In WS Pro Upstream/downstream tracing is easy for a single object. Obtaining a single useful value (i.e. property count) is easy for multiple objects. Combining the two is very difficult at the moment in WS Pro I want to be able to obtain, eithe...