Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

Ideas

Showing 181 of 1372

I want Infoworks' "Export maxima to GIS" to include the below parameters to assist scour protection design within 2D Zone

1. For shear-stress-based design 1.1 Max Shear Stress (in N/m2 with at least 1 digit after the decimal point) 1.2 Hydraulic Slope at Max Shear Stress (in percent with at least 3 digits after the decimal point) 2. For velocity-based design 2.1. Max...
Phuong Mai over 3 years ago in InfoWorks ICM / Export Data / GIS Layers / Simulations 1 Gathering support

Add support for Esri .lyrx files in InfoWorks and InfoAsset Manager

LYRX files can store multiple layers and/or multiple group layers at the root level. LYR files are the extension used in Esri's ArcGIS versions 10. X and ArcGIS Desktop. LYR files can only store a single layer or a single group layer at the root l...
Tony Andrews about 1 year ago in InfoWorks ICM / Data Exchange / Export Data / GIS Layers / Import data 0 Will not implement

Implement an optimising tool back into WS Pro

Develop an optimiser tool similar to the InfoWater Designer tool for WS Pro. Optimatics Optimiser is expensive so does not allow all of the market access.
Guest about 1 year ago in InfoWorks WS Pro / Automation 0 For Review

Allow ICM to use Arc GIS Pro in the GeoPlan

Important as Arc Map as used in InfoSWMM is no longer going to be supported by ESRI. InfoSWMM to ICM users are asking about Arc GIS Pro support as they are also often users of InfoWater Pro.
Robert Dickinson over 2 years ago in InfoWorks ICM / Data Exchange 3 Will not implement

The ability to create multiple Selection Lists at once

I am currently working on a model with a large number of DMAs. This means I have to select each specific area, and save this as a selection list - so I can easily identify areas in the future. This is a very time consuming task, and the ability to...
Sam Bonnington over 2 years ago in InfoWorks WS Pro / Automation 1 Gathering support

Max or Min Flow values should not depend on the pipe direction. i.e. the value being positive or negative depend on the pipe direction

Currently, if the flow direction through the pipe is opposite to the direction of the pipe drawn it shows as a negative flow value. So if the flow goes both direction during the run, smaller positive value shows as the maximum flow and larger nega...
Guest almost 5 years ago in InfoWorks WS Pro / Other 0 Gathering support

Open/Closed Valve Control - Live Data

When using an open/closed valve, setting a time profile to describe the opening and closing pressures, it would be useful to be able to load values form Live Data. It should be possible to connect the valve to 2 different live datas: one live data...
Paolo Boiardi over 1 year ago in InfoWorks WS Pro / Engine 0 For Review

As an organisation we would like to export the data exposed in show details view

As an organisation we would like to export the data exposed in show details view in order to assist with reporting in relation disc storage/ utilisation i.e. ID associated with Model Group. We store all our DAP models within a single Db so collec...
Richard Robinson about 5 years ago in InfoWorks ICM / Export Data / Workgroup 0 Gathering support

In some types of elements the result of the simulation between consecutive time step are very different (oscillations).

Simulation results very differents between consecutive calculation times in series or cascade regulation elements; such as, pressure regulating valves (PRV), float valves (FLV), pumps, ...
Juan Carlos Ortega over 2 years ago in InfoWorks WS Pro / Engine 2 Already exists

Insufficient channel modeling

Impossibility of simulating the operation of a "real" channel with different sections created by different cameras: derivation, shipones, ...
Juan Carlos Ortega over 2 years ago in InfoWorks WS Pro / Engine 0 In progress