As a user it is good to allow tab windows to take it out to the second or third display

Tab windows are not allowed to move main window to second display.
Guest almost 5 years ago in InfoWorks WS Pro 0 Will not implement

As a user of InfoWorks WS PRO, I would like to better simulate FMV valves

In InfoWorks WS PRO is possible to simulate FMV valves, but I would like to introduce a "deviation" option to better simulate it. I give an example: imagine a valve whose pressure setting is 2 Bar if flow is from 0 to 10 L/s, and 2.5 Bar if flow i...
Paolo Boiardi over 2 years ago in InfoWorks WS Pro / Engine 0 Gathering support

I would like to create a template for model import from GIS to XPSWMM

When you go exchange data from GIS to XPSWMM you need to find all the fields you want each time and rename all the field for GIS compatibility. I would like to create a standard template once and use that template for each model and each time I ne...
Guest about 5 years ago in Other Product Ideas / Storm, Sewer, Flood Modeling 0 Gathering support

Copy all the scenarios from a Model

Impossible to make a subsystem copy of a model (with different scenarios) that brings all the scenarios to the new model when I make a copy of the selected nodes and links. At this moment, a copy only brings the current scenario.
Juan Carlos Ortega over 2 years ago in InfoWorks WS Pro / Data Exchange 0 Gathering support

Creation of the Pump element independent of its grouping in the Pumping Station as included in usual infrastructure catalogs (GIS)

Useful for maintaining the unique relationship between the elements of a supply network and the Infoworks model objects.
Juan Carlos Ortega over 2 years ago in InfoWorks WS Pro / Operations 2 Will not implement

The "join model" tool does not work correctly with Scenarios

The Infoworks Join Model Tool does not work correctly with Topologies and Controls containing different scenarios In the resulting united model, it maintains the four scenarios, but in all four scenarios the Topology and Control are the same, it r...
Juan Carlos Ortega over 2 years ago in InfoWorks WS Pro / Data Exchange 0 Gathering support

Respect the text separators of the operating system used by the equipment.

Respect the text separators of the operating system used by the equipment.
Juan Carlos Ortega over 2 years ago in InfoWorks WS Pro / Data Exchange 3 Gathering support

As a user, I would like to be able to export node max stage for all different global storms when exporting to GIS in XPSWMM.

When exporting results to GIS, it should export all the storms that are selected, so that I don't need to manually extract the information and piece them together.
Guest over 5 years ago in Other Product Ideas / Storm, Sewer, Flood Modeling 0 Gathering support

It would be great to add PMP (probable maximum precipitation) calculator to XPSWMM and XPSTORM

It would be great to add PMP (probable maximum precipitation) calculator to XPSWMM and XPSTORM
Guest over 5 years ago in Other Product Ideas / Storm, Sewer, Flood Modeling 0 Gathering support

As a user of InfoWorks WS PRO, I would like to better simulate FMV valves

In InfoWorks WS PRO is possible to simulate FMV valves, but I would like to introduce a "deviation" option to better simulate it. I give an example: imagine a valve whose pressure setting is 2 Bar if flow is from 0 to 10 L/s, and 2.5 Bar if flow ...
Paolo Boiardi over 5 years ago in InfoWorks WS Pro / Engine 0 Gathering support