Skip to Main Content
Autodesk
Status For Review
Categories Engine
Created by Daniel Alexander
Created on Mar 6, 2026

Sub‑Minute Timesteps or Enhanced Transient Controls in InfoWorks WS Pro

The minimum 1‑minute hydraulic timestep in InfoWorks WS Pro prevents realistic modelling of fast‑acting control valves that respond within seconds. This leads to overstated burst volumes and flooding impacts.

Workaround:
Users currently scale system storage and interpret each timestep as 1 second, then manually adjust outputs. This is approximate and does not represent short‑duration transient effects.

Note:
Even with sub‑minute timesteps, full transient impacts would not be accurately simulated within the WS Pro hydraulic engine.

Requested Enhancement:

  • Primary: Support hydraulic timesteps down to ~1 second.

  • Alternative: Add more detailed control‑logic options within the transient simulation engine to model rapid valve actions without timestep scaling.

Benefit:
Improves representation of rapid control responses and removes the need for artificial scaling workarounds.

  • Attach files