Skip to Main Content
Autodesk

Include the volume of the downstram manhole ONLY if selected

Change behaviour of Storage Operations: Calculate total storage... function. The current behaviour is unintuitive and incorrect.

  • Attach files
      Drop here to upload
    • Admin
      Samer Muhandes
      Reply
      |
      Feb 26, 2025

      Thank you for the comment and the suggestion, would you please elaborate on the expected behaviour.

      We currently provide you with three volumes, Conduits, Manholes and Total (sum), so you have the option to check the volume available within the conduit. I am going to mark this as (Already Exists) but if you have suggestions to make it better, please add further comments and I will change the status.

      If you believe that the calculations are incorrect, please let our customer success team know so they can investigate and we can treat this as a bug to be resolved. I've just done a napkin calculation for the volume of this conduit (length = 1m and diameter = 3m) and the resulting volume was correct V = 7.06m3.