Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

Ideas

Showing 660 of 1370

Allocate a subcatchment’s flows among several nodes

This is an idea from CDM Smith == I have an engine feature idea that has occurred to me at various times but never acted on. Today I was discussing an InfoWorks model with a junior colleague. It would clearly help us in this model to be able to al...
Guest almost 5 years ago in InfoWorks ICM / Hydraulics 1 Gathering support

As a user, I would like the computing time to be reported as clock time rather than CPU time in XPSWMM 2D

I just noticed this when trying to run a test on model speed. This is with the “CPU” Extreme option and 4 CPUs selected. The clock time is about 16 minutes, but the elapsed time is showing at 58 (close to 16x4). I think the ET is counting CPU time...
Guest almost 5 years ago in Other Product Ideas / Storm, Sewer, Flood Modeling 0 Gathering support

Select objects outside polygon in SQL

In Infoworks ICM the SQL select has a spatial search option where I can, for example, select all nodes within a 2D zone. I am wanting to select all nodes outside the 2D zones, and this I am unable to do as inverting the selection will select all ...
Guest about 5 years ago in InfoWorks ICM / SQL 0 Gathering support

As an organisation we want InfoAsset Manager to be able to show dimensions relative to fixed points

In plans underground assets are often positioned using dimensions relative to a fixed point (pe corner of a house). InfoAsset Manager should be able to create dimensions like that.
Bram Calle about 5 years ago in Other Product Ideas / Asset Management 0 For Review

Interconnect 2 longprofiles

When 2 sim results are placed on 1 long profile (with the Open as alternate result option) only the water heights are used to visualize sim2. Sometimes these pipes have different invert levels which makes a comparison on 1 long profile rather usel...
Guest about 5 years ago in InfoWorks ICM / Long Section / Profile 0 Gathering support

TVD connector input fields longer than 64 characters

The "input" fields for TVD connectors are currently limited to 64 characters. I have TSDB streams with names longer than 64 characters, and I would like to be able to use those streams as inputs to the TVD connectors.
Iain Scott over 5 years ago in InfoWorks ICM / Time Series DB 0 Gathering support

InfoAsset Planner - View Multiple CCTV Videos Concurrently in Facility Assessment Tool

I have had a request from the Asset Condition and Reliability team to be able to view CCTV survey videos side-by-side when a pipe has multiple CCTV surveys. In the same way that the longsection view shows concurrent surveys, being able to see conc...
Bradley Nissley over 5 years ago in Other Product Ideas / Asset Management 0 For Review

InfoSWMM from InfoSewer should allow the user to pick a scenario on import. It is a feature of InfoSWMM to convert an InfoSewer MXD and IE

We only allow the user to import the active scenario in InfoSewer. If a user does not have InfoSewer then he or she must guess which is the active scenario. It would better to have a dialog to allow the user to import their selected and needed sce...
Guest over 5 years ago in Other Product Ideas / Storm, Sewer, Flood Modeling 0 Gathering support

Hyperlinks to specific pages not just files/documents

When adding hyperlinks to features within the properties, enable the ability to link to a specific page within the document itself rather than just a folder location or document opening on the first page.
Guest over 5 years ago in InfoWorks ICM / Other 0 Gathering support

Ground Surface Comparison with sceanarios

I am trying to calculate the excavation/fill volume by comparing my existing model with the proposed one. I know we can open simulation results with “As alternate results for comparison” which allows us to compare flooding depth from two different...
Guest over 5 years ago in InfoWorks ICM / Terrain 0 Gathering support