Skip to Main Content
Autodesk
ADD A NEW IDEA

Clear

Ideas

Showing 120 of 1370

Open/Closed Valve Control - Live Data

When using an open/closed valve, setting a time profile to describe the opening and closing pressures, it would be useful to be able to load values form Live Data. It should be possible to connect the valve to 2 different live datas: one live data...
Paolo Boiardi over 1 year ago in InfoWorks WS Pro / Engine 0 For Review

In some types of elements the result of the simulation between consecutive time step are very different (oscillations).

Simulation results very differents between consecutive calculation times in series or cascade regulation elements; such as, pressure regulating valves (PRV), float valves (FLV), pumps, ...
Juan Carlos Ortega over 2 years ago in InfoWorks WS Pro / Engine 2 Already exists

Insufficient channel modeling

Impossibility of simulating the operation of a "real" channel with different sections created by different cameras: derivation, shipones, ...
Juan Carlos Ortega over 2 years ago in InfoWorks WS Pro / Engine 0 In progress

To be able to graph refill/depletion rate and/or survival time on reservoirs and towers

in WS Pro
Guest about 5 years ago in InfoWorks WS Pro 1 Gathering support

Demand Area Analysis for partially metered areas

Demand Area Analysis was originally intended for networks where the unprofiled demand was unmetered. When domestic (unprofiled) metering became more prevalent Innovyze introduced “Current Average Specific Consumption (l/p/day)” in the calculation ...
Guest over 1 year ago in InfoWorks WS Pro / Productivity 2 For Review

WS Pro to allow for maxconc at node/hydrant

No description provided
Guest over 5 years ago in InfoWorks WS Pro / Water Quality 1 Gathering support

Option to display in the same time assignments of properties to nodes and to pipes

Add an option to map to display in the same time assignments of properties to nodes and to pipes. At the moment it is not possible as the 'Customer Point Demand Assignment' option is a radio button.
Guest over 5 years ago in InfoWorks WS Pro 1 Will not implement

A simple way to straighten short links to display symbols more clearly

When using the "Expand Short Links" option I find that the expanded links will inherit some geometric points from the adjacent links, and hence symbols for valves, meters etc may not display too well if adjacent to a pipe bend. It would be useful ...
Owen Lewis over 5 years ago in InfoWorks WS Pro / Other 1 Gathering support

I want to be able to see what connected Agents are doing and trouble shoot connections from within WS Pro

A command centre program for WS Pro/IWLive runs which shows connected agents and marshallers and all the runs in a simulation workgroup in one place. Better simulation workgroup diagnostics. I am trying to trouble shoot remote VPN issues and the ...
Ann Pugh over 5 years ago in InfoWorks WS Pro 0 Will not implement

Populate Pump run schedule based on telemetry data in WS Pro

As a planning modeler calibrating within WS Pro, I want to use the "Load from Live Data" tool on pumps in Plan mode to populate the Control Data timeseries profile based on a data stream of 1's and 0's indicating on/off. While this is already avai...
Guest over 4 years ago in InfoWorks WS Pro / Telemetry 0 Gathering support