Continuous Matched Soffits or Inverts Snapping

It would be useful if all pipes in a junction automatically snapped to match either soffits or inverts. There is a variable in the Network Design Criteria for 'Level Soffits' or 'Level Inverts' so potentially this option could be used for the live...
Ian George about 1 month ago in InfoDrainage / Productivity 0 For Review

Retaining CAD files / Orphaning

When CAD files are imported to InfoDrainage they retain the link to the CAD file, like a CAD Xref which is good. However if that file is moved, or InfoDrainage cannot access it, an error box is prompted and the entire CAD file is just deleted from...
Ian George 26 days ago in InfoDrainage / Productivity 0 For Review

Add max pipe flow to the pipe properties window

Max pipe flow (theoretical pipe full) is not listed in pipe properties, as it was previously in MicroDrainage. It was a useful feature.
Ian George 3 months ago in InfoDrainage / Productivity 0 For Review

Ability to look at multiple phases (surface and foul networks together) in 3D

Being able to view both surface and foul networks within MicroDrainage was always a very useful feature to visualise crossing points in the network and it doesn't look to have been included in InfoDrainage.
Henry Wilkinson 9 months ago in InfoDrainage / Productivity 1 For Review

Save phase results seperately

When working with multiple phases I would like to be able to run one phase (exclude all others from analysis) and have the results saved. Results should only be overwritten when a new run on the same phase is completed.
Andrew Komarnycky about 1 year ago in InfoDrainage / Productivity 0 For Review

Graphical editing in Longsection

Being able to manually drag pipes up/down and alter their gradient in the long section graphics, was an extremely efficient workflow in Microdrainage, especially when using min. pipe design levels to dictate land-raise FGLs. Can this function be c...
Guest 11 months ago in InfoDrainage / Productivity 0 For Review

show upstream and downstream cover depth for connections

MicroDrainage used to show this its useful for checking cover to pipes are correct
Matt Hare over 1 year ago in InfoDrainage / Productivity 0 For Review

Pipe clash detection when foul network phase is active

When working through clashes between surface water and foul networks, you can only access the pipe clash analysis within surface water analysis tab. This means if I want to change the depth of the foul network to avoid the clash then I have to swa...
Henry Wilkinson 9 months ago in InfoDrainage / Productivity 1 For Review

Show manhole types in manhole schedule export

Manhole schedules need to feature cover types (D400, C250 etc), manhole types (Type A, B, C in Scotland etc) and whether they're a backdrop or a headwall etc. Having a feature to assign this based on location on site (cover type), depth to soffit ...
Guest over 1 year ago in InfoDrainage / Productivity 0 For Review

Allow changing displayed simple junction size

In plan view we are able to change the sizes of icons, labels, proper manholes and many other parts of our pipe networks, but the symbology for simple junctions is fixed in size (at about 1.2m?) and cannot be changed, which makes modelling, for ex...
Guest about 1 year ago in InfoDrainage / Productivity 0 For Review