it would be great if the "splitting lines" function can be applied to network results lines too, which would help a lot if we need to break up a large amount of NRLs into multiple segments rather than redrawing them.
Guest over 2 years ago in InfoWorks ICM / Hydraulics / Results 0 Gathering support

I would like more informative error messages when trying to Change an ID

I tried to change the ID for a pump, but I overlooked the “Target Element Type” dropdown, which was automatically set to junction. It took me a while to realize my mistake. It might be helpful to other users if the error messages/warnings (see be...
Guest over 5 years ago in InfoWater Pro / Productivity 0 Gathering support

InfoWater for QGIS

ArcMap and ArcGIS Pro are expensive and slow. QGIS is free and fast.
Colin Ricks over 5 years ago in InfoWater Pro 0 Will not implement

Simplify the Ground Water Model

Simplify the InfoWorks Ground Water model Or GIM by using only the Ground layer instead of two layers Soil and Ground. Don’t use the soil store component of the GIM. Innovyze, please simplify the conceptual design of the GIM by reducing it to o...
ROBERT DICKENSON almost 3 years ago in InfoWorks ICM / Hydraulics 0 Gathering support

Create preset 2D inflow equation

Similar to inlet capacity, have the ability to create 2D inflow equations relative to inlet size and control depending on weir or orifice curves. This will allow the user to increase or change 2D inflow control easier and more standardized.
Guest almost 6 years ago in InfoWorks ICM / Hydraulics 1 Gathering support

Add multiple rows to the InfoWater "Rule Header" DB table

In the "Pipe Control" or "Node Control" DB tables, I can insert or append multiple rows at once. In the "Rule Header" DB table, I can only insert or append one row at a time, and each row must have an ID. Please make the behavior of this table co...
Colin Ricks almost 3 years ago in InfoWater Pro 0 Under consideration

Add username to temp folder names to allow multiple users to model on the same cloud computer at the same time

Could InfoWater/InfoSWMM change how they name temp folders? Right now, if two users initialize a model on the same cloud computer at the same time, both models might try to use the same temp folder (like HMVDB1). Renaming temp folders to include t...
Andrew Fugal almost 6 years ago in InfoWater Pro / Productivity 0 Will not implement

Split pipes using the InfoWater "Digitize Network" tool

The "Digitize Network" tool can be used to draw new pipes and junctions, but does not split existing pipes, even though you can snap to existing pipes and add a junction. This can cause confusion because it appears that the pipe has been split whe...
Colin Ricks almost 6 years ago in InfoWater Pro 1 Under consideration

Automatically autofit DB table column widths

No description provided
Colin Ricks almost 6 years ago in InfoWater Pro / Productivity 1 Gathering support

Reset the active facilities query without changing scenarios

When scenarios use a query set to define the active facilities, it would be useful to be able to re-run the query and update the active/inactive facilities without changing scenarios. Changing scenarios can be very slow for large models.
Colin Ricks almost 6 years ago in InfoWater Pro / Productivity 1 Will not implement